7.Reversing Models ONLY

Basket (tumbler) dryer should never be operated with less than a 30 lb. load (dry weight). The size of the load will affect the coast-down and dwell (stop) times. The basket (tumbler) must come to a complete stop before starting in opposite direction.

a.Microprocessor Models

1)Spin and stop are not adjustable in the Automatic Mode and have been pre-programmed into the microprocessor controller (computer) for 150-seconds spin time in the forward direction, 120-seconds in the reverse direction, and a 5-second dwell (stop) time.

2)Spin times and stop times are adjustable in the Manual (timed) Mode.

b.Dual Timer Models

1)Both dwell (stop) and basket (tumbler) spin time are adjustable. Refer to the illustration on page 41.

8.Check to insure that ALL set screws (i.e., tumbler drive, idler, etc.) are tight.

J.PREOPERATIONAL INSTRUCTIONS

1.To start the dryer:

a.Microprocessor (computer) dryers

1)The L.E.D. (light emitting diode) display will read "FILL".

2)Press the "E" on the touchpad of the keyboard.

3)The dryer will start and the display will quickly show "Ld30", "F180", the dryer will start, and the L.E.D. (light emitting diode) display will show "dr30".

4)To stop the dryer, open the main door and press "CLEAR/STOP" key. Refer to the User's Manual for detailed operating instructions.

b.Dual Timer Dryers

1)Turn drying timer knob for a time of 20 minutes.

2)Select "High Temp".

3)Push "Push To Start" Switch.

31

Image 35
Contents MDG-75 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications Component Identification Dryer Rear View Illus. No Location Requirements Installation ProceduresUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Not be Reduced Anywhere Down Stream of the Dryer Page Page Electrical Information MDG-75 GAS Page 3+$6 ‘ /&75,&$/&211&7,216/$6 Page Page GAS Information 48, 3523$1 Page Page Preparation for OPERATION/START-UP Gas Dryers Preoperational TestsPage Preoperational Instructions Shut Down Instructions Parts SERVICE/PARTS InformationService Returning Warranty Cards Warranty InformationCleaning Routine MaintenanceDays Days After Installation and Every 6 Months Thereafter AdjustmentsProcedure for Functional Check Replacement Components Page Page 1* /*1’ Reversing Timer Spin and Dwell AdjustmentsData Label Technical InformationApplicable Approval Seals From the Machine Toallowaccess for CLEANING,ADJUSTING Troubleshooting70 3$ Microprocessor Computer Models Blower and Fan motor is not operating does not start Loose connection in main door switch circuit Page GAS Models Failed microprocessor controller computer Dryer operates but is taking too long to dry Page AA. Condensation on main door glass Timer Models Blower/Fan motor is not operating does not start Page Dryer operates but is taking too long to dry Page Condensation on main door glass Page 01/07/998-50