H. PREPARATION FOR OPERATION/START-UP

The following items should be checked before attempting to operate the dryer:

1.Read ALL "CAUTION," "WARNING," and "DIRECTION" labels attached to the dryer.

2.Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to the back side of the top front control/service door. In the case of 208 VAC or 230/240 VAC, THE SUPPLY VOLTAGE MUST MATCH THE ELECTRIC SERVICE EXACTLY.

3.GAS MODELS - check to assure that the dryer is connected to the type of heat or gas indicated on the dryer data label.

4.GAS MODELS - the sail switch damper assembly was installed and adjusted at the factory prior to ship- ping. However, each sail switch adjustment must be checked to assure that this impor- tant safety control is functioning. (Refer to page 30 for Sail Switch Adjustment.)

5.GAS MODELS - be sure that ALL gas shut-off valves are in the open position.

6.Be sure ALL side and base panels are on the dryer.

7.Check ALL service doors to insure that they are closed and secure.

8.Be sure the lint door is securely in place.

9.Rotate the basket (tumbler or drum) by hand to be sure it moves freely.

10.Check bolts, nuts, screws, terminals, and fittings for security.

11.Check tumbler bearing set screws to insure they are ALL tight.

28

Image 32
Contents MDG-75 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Dryer Rear View Illus. No Installation Procedures Location RequirementsUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Not be Reduced Anywhere Down Stream of the Dryer Page Page Electrical Information MDG-75 GAS Page 3+$6 ‘ /&75,&$/&211&7,216/$6 Page Page GAS Information 48, 3523$1 Page Page Preparation for OPERATION/START-UP Preoperational Tests Gas DryersPage Preoperational Instructions Shut Down Instructions Parts SERVICE/PARTS InformationService Warranty Information Returning Warranty CardsRoutine Maintenance CleaningDays Adjustments Days After Installation and Every 6 Months ThereafterProcedure for Functional Check Replacement Components Page Page Reversing Timer Spin and Dwell Adjustments 1* /*1’Technical Information Data LabelApplicable Approval Seals Troubleshooting From the Machine Toallowaccess for CLEANING,ADJUSTING70 3$ Microprocessor Computer Models Blower and Fan motor is not operating does not start Loose connection in main door switch circuit Page GAS Models Failed microprocessor controller computer Dryer operates but is taking too long to dry Page AA. Condensation on main door glass Timer Models Blower/Fan motor is not operating does not start Page Dryer operates but is taking too long to dry Page Condensation on main door glass Page 01/07/998-50