American Dryer Corp ID-120 SPECIFICATIONS/COMPONENT Identification, Specifications GAS and Steam

Page 10

SECTION II

SPECIFICATIONS/COMPONENT IDENTIFICATION

A. SPECIFICATIONS (GAS AND STEAM)

MAXIMUM CAPACITY (DRY WEIGHT)

120 lbs

 

 

 

54.43 kg

BASKET (TUMBLER) DIAMETER

44-1/2”

 

 

 

113 cm

BASKET (TUMBLER) DEPTH

42-1/2”

 

 

 

108 cm

BASKET (TUMBLER) MOTOR

1 HP

 

 

 

0.746 kw

BLOWER MOTOR

3 HP

 

 

2.238 kw

DOOR OPENING (DIAMETER)

31-3/8”

 

 

 

79.7 cm

BASKET (TUMBLER) VOLUME

38.2 cu. ft.

 

1.08 cu. m.

DRYERS PER 20’/40’ CONTAINER

 

 

3/7

 

 

 

 

 

 

 

 

DRYERS PER 45’/48’ TRUCK

 

 

9/9

 

 

 

 

 

 

 

 

 

VOLTAGE AVAILABLE

208-460v

3, 4w

50/60 Hz

 

 

 

 

 

 

HEAT INPUT

415,000 btu/hr

 

104,580 kcal/hr

Gas

APPROX. WEIGHT (UNCRATED)

1,500 lbs

 

 

 

680.4 kg

APPROX. WEIGHT (CRATED)

1,725 lbs

 

 

 

782.5 kg

 

 

 

 

 

AIRFLOW

2,800 cfm

 

 

79.29 cmm

 

INLET PIPE SIZE

1”

 

 

 

2.54 cm

 

COMPRESSED AIR @ 80 PSI (5.51 BARS)

2.5 cfh

 

 

 

0.07 cmh

 

VOLTAGE AVAILABLE

208-460v

3, 4w

50/60 Hz

 

 

 

 

 

 

 

Steam

APPROX. WEIGHT (UNCRATED)

1,650 lbs

 

 

 

748.4 kg

APPROX. WEIGHT (CRATED)

1,875 lbs

 

 

 

850.5 kg

HEAT INPUT

 

13 Bhp

 

 

 

 

 

STEAM CONSUMPTION

450 lbs/hr

 

200.2 kg/hr

AIRFLOW

2,800 cfm

 

 

79.29 cmm

 

INLET PIPE SIZE

 

1-1/4”

 

 

 

 

 

 

 

 

 

COMPRESSED AIR @ 80 PSI (5.51 BARS)

3.25 cfh

 

 

 

0.09 cmh

 

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

IMPORTANT: Dryers must be provided with a clean, dry, regulated 80 PSI +/- 10 PSI (5.51 bars +/- 0.69 bars) air supply.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

6

Image 10
Contents ID-120 Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification Specifications GAS and SteamSpecifications IDG-120 Gas IDS-120 Steam Component Identification Dryer Rear View Illus. No Installation Procedures Location RequirementsUNPACKING/SETTING UP Lift the console module off the dryer base C Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements General Exhaust Ductwork InformationPage Ducting Horizontal and Vertical Page Page Electrical Information Electrical RequirementsID-120 Gas and Steam Only Electrical Connections GAS Information Type of GAS Page Page Steam Information Bars. Refer to Steam DamperAir System Connections, item 4Page COM Pressed AIR Pressure AIR Supply Page Compressed AIR Preparation for OPERATION/START-UPPreoperational Tests Page Basket Tumbler Coating Operating Instructions Shut Down Instructions Service SERVICE/PARTS InformationParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningSteam Dryers Adjustments LubricationReversing Timer SPIN/DWELLADJUSTMENTS SectionviiProcedure for Functional Check Replacement Components Page Datalabel Information Data LabelSerial Number For Phase 7 Models P O R T a N TFor Dual Timer Models ADC113330 1 08/31/01-25