American Dryer Corp ID-120 installation manual Unpacking/Setting Up

Page 15

10. The dryer must be installed with provisions for adequate combustion and make-up air supply.

CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint build up.

B. UNPACKING/SETTING UP

Remove protective shipping material (i.e., plastic wrap, and/or optional shipping box) from dryer.

IMPORTANT: Dryer must be transported and handled in an upright position at ALL times.

The dryer can be moved to its final location while still attached to the skid or with the skid removed. To unskid the dryer, locate and remove the four (4) lag bolts securing the base of the dryer to the wooden skid. Two (2) are at the rear base, and two (2) are located in the bottom of the lint chamber. To remove the two (2) lag bolts located in the lint chamber area, remove the lint drawer and the three (3) Phillips head screws securing the lint door in place.

1.Leveling Dryer

a.To level the dryer, place 4-inch (10.16 cm) square metal shims (refer to the illustration above) or other suitable material under the base pads. It is suggested that the dryer be tilted slightly to the rear.

11

Image 15
Contents ID-120 Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsStandards Specifications GAS and Steam SPECIFICATIONS/COMPONENT IdentificationSpecifications IDG-120 Gas IDS-120 Steam Component Identification Dryer Rear View Illus. No Location Requirements Installation ProceduresUNPACKING/SETTING UP Lift the console module off the dryer base C Dryer Enclosure Requirements Fresh AIR Supply Requirements General Exhaust Ductwork Information Exhaust RequirementsPage Ducting Horizontal and Vertical Page Page Electrical Requirements Electrical InformationID-120 Gas and Steam Only Electrical Connections GAS Information Type of GAS Page Page Bars. Refer to Steam DamperAir System Connections, item 4 Steam InformationPage COM Pressed AIR Pressure AIR Supply Page Preparation for OPERATION/START-UP Compressed AIRPreoperational Tests Page Basket Tumbler Coating Operating Instructions Shut Down Instructions SERVICE/PARTS Information ServiceParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Cleaning Routine MaintenanceSteam Dryers Lubrication AdjustmentsSectionvii Reversing Timer SPIN/DWELLADJUSTMENTSProcedure for Functional Check Replacement Components Page Data Label Datalabel InformationSerial Number P O R T a N T For Phase 7 ModelsFor Dual Timer Models ADC113330 1 08/31/01-25