American Dryer Corp ID-120 installation manual COM Pressed AIR Pressure AIR Supply

Page 33

4.Steam Damper Air System Connections

This dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of compressed air of 0.75 CFH. The air connection is made to the steam damper solenoid valve, which is located at the rear of the top console.

a. Air Requirements

COM PRESSED

AIR PRESSURE

AIR SUPPLY

 

 

 

 

 

Normal

80 PSI

5.51 bars

 

 

 

Minimum Supply

70 PSI

4.82 bars

 

 

 

Maximum Supply

90 PSI

6.21 bars

 

 

 

Shaded areas are stated in metric equivalents

b.Air Connection

Air connection to system --- 1/8” F.P.T.

c.No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 PSI (5.51 bars) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.

5.Steam Damper System Operation

The steam damper, as shown in the top illustration (Diagram 1) on page 30, allows the coil to stay constantly charged eliminating repeated expansion and contraction. When the damper is opened, the air immediately passes through the already hot coil, providing instant heat to start the drying process. When the damper is closed, ambient air is drawn directly into the basket (tumbler), allowing a rapid cool down.

Diagram 1 shows the damper in the heating (open) mode, allowing heat into the basket (tumbler).

Diagram 2 shows the damper in the cool down (closed) mode, pulling ambient air directly into the basket (tumbler) without passing through the coils.

NOTE: With the dryer off or with no air supply, the steam damper is in cool down mode as shown in Diagram 2 (refer to the illustration on the following page).

29

Image 33
Contents ID-120 Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsStandards Specifications GAS and Steam SPECIFICATIONS/COMPONENT IdentificationSpecifications IDG-120 Gas IDS-120 Steam Component Identification Dryer Rear View Illus. No Location Requirements Installation ProceduresUNPACKING/SETTING UP Lift the console module off the dryer base C Dryer Enclosure Requirements Fresh AIR Supply Requirements General Exhaust Ductwork Information Exhaust RequirementsPage Ducting Horizontal and Vertical Page Page Electrical Requirements Electrical InformationID-120 Gas and Steam Only Electrical Connections GAS Information Type of GAS Page Page Bars. Refer to Steam DamperAir System Connections, item 4 Steam InformationPage COM Pressed AIR Pressure AIR Supply Page Preparation for OPERATION/START-UP Compressed AIRPreoperational Tests Page Basket Tumbler Coating Operating Instructions Shut Down Instructions SERVICE/PARTS Information ServiceParts Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Cleaning Routine MaintenanceSteam Dryers Lubrication AdjustmentsSectionvii Reversing Timer SPIN/DWELLADJUSTMENTSProcedure for Functional Check Replacement Components Page Data Label Datalabel InformationSerial Number P O R T a N T For Phase 7 ModelsFor Dual Timer Models ADC113330 1 08/31/01-25