American Dryer Corp MLG32PDB installation manual Maytag Co

Page 13

2.The dryer must not be installed or stored in an area where it will be exposed to water or weather.

3.The dryer is for use in noncombustible locations.

4.Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements in Section D).

5.Clearance provisions must be made from noncombustible construction as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

Even though a 12-inch clearance is acceptable, it is recommended that the rear of the dryer be positioned approximately 2 feet away from the nearest obstruction, i.e., wall, for ease of installation, maintenance, and service. (Refer to the illustration below.)

6.Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

7.Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements in Section E).

8.Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements in Section E).

9.The dryer must be installed with a proper exhaust duct connection to the outside.

10.The dryer must be installed with provisions for adequate combustion and make-up air supply.

CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint build up.

IMPORTANT: Dryer must be installed in a location/environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C).

IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.

113062 - 16

Maytag Co.

9

Image 13
Contents MLG32PDB Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Warranty Information Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsMaytag Co Specifications SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation of the Dryer Maytag Co Fresh AIR Supply Requirements Dryer Enclosure RequirementsMaytag Co Exhaust Requirements Gauge 0.0195-inches 0.50 mm thick Maytag Co 113062 Maytag Co Electrical Requirements Electrical InformationSingle-Phase 1Ø Electrical Connection Leads Electrical Service Specifications PER Tumbler GAS Information Type of GAS Maytag Co Preoperational Tests Preparation for OperationNatural Gas Inches Water Column Liquid Propane L.P. Gas Basket Tumbler Coating Shutdown InstructionsStarting the Dryer Operating InstructionsService SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Cleaning Routine MaintenanceSuggested Cleaning Schedule Lubrication AdjustmentsData Label Location Dryer Data Label InformationData Label 16 08/08/08