Providing local codes permit, power to the dryer can be made by use of a flexible U.L. listed power cord or pigtail (wire size must conform to the rating of the dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer.
ELECTRICAL SERVICE SPECIFICATIONS (PER TUMBLER)
A separate circuit breaker must be provided for each tumbler/pocket.
NOTES: Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.
SERVICE | PHASE | WIRE | APPROX. | MINIMUM | CIRCUIT | |
VOLTAGE | SERVICE | AMP DRAW | WIRE SIZE | BREAKER | ||
| ||||||
|
|
|
|
|
| |
120 | 1Ø | 2 | 8.7 | * | 15 | |
|
|
|
|
|
| |
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes. | 8/5/08 |
NOTE: Contact factory for electrical information not listed.
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation.