WARNING: Test ALL connections for leaks by brushing on a soapy water solution (liquid detergent works well).

WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!

It is important that gas pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount of appliance BTUs being supplied.

H. PREPARATION FOR OPERATION

The following items should be checked before attempting to operate the dryer:

1.Read ALLCAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.

2.Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label.

3.GAS MODELS - check to assure that the dryer is connected to the type of heat or gas indicated on the dryer data label.

4.The sail switch damper assembly was installed and adjusted at the factory prior to shipping. However, each sail switch adjustment must be checked to assure that this important safety control is functioning.

5.Check bolts, nuts, screws, terminals, and fittings for tightness.

6.GAS MODELS - be sure that ALL gas shutoff valves are in the open position.

7.Be sure ALL back guard panels and service box covers have been replaced.

8.Check the lint door to assure that it is closed and secured in place.

9.Rotate the basket (tumbler) by hand to be sure it moves freely.

I.PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.

1.Turn on electric power to the dryer. a. Coin Models Only

1)The display will read “0 minutes” for both baskets (tumblers) and the price required to start a cycle.

2)Insert the proper number of coins into coin acceptor. Once the correct amount needed to start the dryer has been inserted, the light emitting diode (L.E.D.) display will read “SELECT CYCLE.”

22

Maytag Co.

113062 - 16

Image 26
Contents MLG32PDB Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Warranty Information Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASMaytag Co Specifications SpecificationsSpecifications Location of the Dryer Installation ProceduresUNPACKING/SETTING UP Maytag Co Dryer Enclosure Requirements Fresh AIR Supply RequirementsMaytag Co Exhaust Requirements Gauge 0.0195-inches 0.50 mm thick Maytag Co 113062 Maytag Co Electrical Information Electrical RequirementsSingle-Phase 1Ø Electrical Connection Leads Electrical Service Specifications PER Tumbler GAS Information Type of GAS Maytag Co Preparation for Operation Preoperational TestsNatural Gas Inches Water Column Liquid Propane L.P. Gas Shutdown Instructions Basket Tumbler CoatingOperating Instructions Starting the DryerParts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Suggested Cleaning Schedule Routine MaintenanceCleaning Adjustments LubricationDryer Data Label Information Data Label LocationData Label 16 08/08/08