2.Electrical Service Specifications
MLG-78II (Gas)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.
B.Circuit breakers are
C.Circuit breakers for
SERVICE |
| WIRE | APPROX. | MINIMUM | FUSING | CIRCUIT | ||
PHASE | AMP DRAW | Dual Element | ||||||
VOLTAGE | SERVICE | WIRE SIZE | BREAKER | |||||
| 60 Hz | 50 Hz | Time Delay | |||||
|
|
|
|
| ||||
120 | 1Ø | 2 | 13 | * | 20 | 20 | ||
208 | 1Ø | 2 | 7.6 | * | 12 | 15 | ||
208 | 3Ø | 3/4 | 4.7 | * | 8 | 15 | ||
240 | 1Ø | 2 | 7 | * | 10 | 15 | ||
240 | 3Ø | 3 | 4.9 | 5.5 | * | 8 | 15 | |
3Ø | 3/4 | 3 | * | 5 | 15 | |||
416 | 3Ø | 3/4 | 3.1 | * | 5 | 15 | ||
460/480 | 3Ø | 3/4 | 2.8 | * | 5 | 15 |
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.