American Dryer Corp ML-78II installation manual Type of GAS

Page 29

2.Technical Gas Data a. Gas Specifications

 

TYPE OF GAS

 

 

 

 

 

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

 

 

 

 

 

Shaded areas are stated in metric equivalents

b.Gas Connections

Inlet connection --- 3/4-inch N.P.T.

Inlet supply size --- 3/4-inch N.P.T. (minimum) Btu/hr input -------- 204,000 (51,408 kcal/hr)

1)Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

 

 

TYP E OF GAS

 

L.P.

 

 

 

 

 

 

 

 

 

 

Conversion Kit

 

BTU

 

 

Natural

 

 

Liquid Propane

MODEL

kcal/hr

 

 

 

Part

Per Hour

 

 

 

 

 

 

 

NUMBER

Rating

Qty.

D.M.S.*

 

Part

Qty.

D.M.S.*

Part

Number

Rating

 

Number

Number

 

 

 

 

 

 

 

 

MLG-78II

204,000

51,408

3

#23

 

140856

3

#42

140810

881655

 

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

* Drill Material Size (D.M.S.) equivalents are as follows:

Natural Gas

#23

=

0.1540” (3.9116 mm).

Liquid Propane Gas

#42

=

0.0935” (2.3749 mm).

25

Image 29
Contents ML-78II Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications MLG-78II Gas Component Identification Page Location Requirements Installation ProceduresBefore Starting the Dryer UNPACKING/SETTING UPDryer Enclosure Requirements Fresh AIR Supply Requirements Horizontal Venting Exhaust RequirementsPage Page Page Electrical Requirements Electrical InformationMLG-78II Gas Electrical Service Specifications PER DryerPage Black Page Page GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Shut Down Instructions Preoperational InstructionsParts SERVICE/PARTS InformationService Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Suggested Cleaning Schedule Routine MaintenanceCleaning Lubrication AdjustmentsTiming Legend Reversing Timer SPIN/DWELL AdjustmentsData Label Data Label InformationSerial Number Procedure for Functional Check Replacement Components P O RTA N T