American Dryer Corp ML-78II Timing Legend, Reversing Timer SPIN/DWELL Adjustments

Page 41

SECTION VII

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer.

Both the dwell (stop) time and the basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Adjustment Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

30

60

90

120

150

 

 

 

 

 

 

DWELL (STOP) TIME

 

 

 

 

 

 

 

 

 

 

 

Adjustment Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

5

6.3

7.6

8.9

10.2

 

 

 

 

 

 

* Values shown are +/- 1-second.

37

Image 41
Contents ML-78II Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications MLG-78II Gas Component Identification Page Location Requirements Installation ProceduresBefore Starting the Dryer UNPACKING/SETTING UPDryer Enclosure Requirements Fresh AIR Supply Requirements Horizontal Venting Exhaust RequirementsPage Page Page Electrical Requirements Electrical InformationMLG-78II Gas Electrical Service Specifications PER DryerPage Black Page Page GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Shut Down Instructions Preoperational InstructionsParts SERVICE/PARTS InformationService Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Suggested Cleaning Schedule Routine MaintenanceCleaning Lubrication AdjustmentsTiming Legend Reversing Timer SPIN/DWELL AdjustmentsData Label Data Label InformationSerial Number Procedure for Functional Check Replacement Components P O RTA N T