American Dryer Corp MDG75V installation manual Specifications

Page 10

SECTION II

SPECIFICATIONS

A. SPECIFICATIONS

MAXIMUM CAPACITY (DRY WEIGHT)

75 lbs

 

34 kg

BASKET (TUMBLER) DIAMETER

37”

 

94 cm

BASKET (TUMBLER) DEPTH

36”

 

91.5 cm

BASKET (TUMBLER) MOTOR

1 HP*

 

0.745 kw

DOOR OPENING (DIAMETER)

21-1/2”

 

54.61 cm

BASKET (TUMBLER) VOLUME

22.4 cu. ft.

 

0.634 cu.m.

EXHAUST CONNECTION (DIAMETER)

8”

 

20.3 cm

AIRFLOW

1000 cfm

 

28.3 cmm

DRYERS PER 20'/40' CONTAINER

 

10/20

DRYERS PER 48'/53' TRUCK

 

24/26

 

VOLTAGE AVAILABLE

120-460v 1ø-3ø 3, 4w 50/60 Hz

Gas

APPROX. WEIGHT (UNCRATED)

721 lbs

 

327 kg

APPROX. WEIGHT (CRATED)

771 lbs

 

349.7 kg

 

 

 

HEAT INPUT

175,000 btuh

 

44,100 kcal/hr

 

INLET PIPE CONNECTION

3/4” F.P.T.**

Shaded areas are stated in metric equivalents

*ALL MDG75V reversing dryers are supplied with two (2) 3-phase (3ø) motors standard: a 1/2 HP (0.37 kw) blower motor and a 1/2 HP (0.37 kw) drive motor.

**Size of piping to dryer varies with installation conditions. Contact factory for assistance.

NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

6

Image 10
Contents MDG75V Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASPage Specifications SpecificationsMDG75V Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements General Exhaust Ductwork InformationPage Page Multiple common Dryer Venting Importantventingreminders Electrical Information Electrical RequirementsMust be Provided SINGLE-PHASE 1Ø Electrical Connections Leads Important a Circuit Servicing Each Dryer Must be Provided Page MDG75V GAS GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests GAS Models onlyBasket Tumbler Coating Preoperational Instructions Shutdown InstructionsService SERVICE/PARTS InformationParts Cleaning Routine MaintenanceSuggested Cleaning Schedule Adjustments LubricationLint Drawer Removal Troubleshooting Microprocessor Controller Computer ModelsBlower motor is not operating does not start Microprocessor controller computer display reads dSFL GAS Models only Dryer operates but is taking too long to dry Dryer is making scraping noise at basket tumbler area Data Label Information Data LabelSerial Number Procedure for Functional Check Replacement Components SectionviiiPage 113160 1 11/27/02-25