A. SPECIFICATIONS

MAXIMUM CAPACITY (DRY WEIGHT)

130 lbs.

 

 

 

60 kg

 

 

 

 

 

 

 

 

 

 

BASKET (TUMBLER) DIAMETER

44-1/2”

 

 

 

113 cm

 

 

 

 

 

 

 

 

 

 

BASKET (TUMBLER) DEPTH

42-1/2”

 

 

 

107.9 cm

BASKET (TUMBLER) MOTOR

3/4 HP

 

 

 

0.560 kw

BLOWER MOTOR

 

3 HP

 

 

 

2.238 kw

DOOR OPENING (DIAMETER)

31-3/8”

 

 

 

79.7 cm

BASKET (TUMBLER) VOLUME

38.2 cu. ft.

 

 

 

1.08 cu. m.

DRYERS PER 20'/40' CONTAINER

 

 

 

 

3/7

 

 

DRYERS PER 45'/48' TRUCK

 

 

 

 

9/9

 

 

 

VOLTAGE AVAILABLE

 

208-460v

3, 4w

50/60 Hz

Gas

HEAT INPUT

375,000 btu/hr

 

 

 

94,500 kcal/hr

APPROX. WEIGHT (UNCRATED)

1,500 lbs.

 

 

 

680.4 kg

APPROX. WEIGHT (CRATED)

1,725 lbs.

 

 

 

782.5 kg

 

AIRFLOW

2,150 cfm

 

 

 

60.88 cmm

 

INLET SIZE

 

 

 

 

1”

 

 

Electric

VOLTAGE AVAILABLE

 

208-600v

3, 4w

50/60 Hz

 

 

 

 

OVEN SIZE

 

 

 

 

 

 

 

 

 

 

 

kw

btu/hr

 

kcal/hr

 

 

AIRFLOW

 

 

72

246,150

 

61,982

 

2,150 cfm

60.88 cmm

 

 

80

273,500

 

68,869

 

2,150 cfm

60.88 cmm

 

VOLTAGE AVAILABLE

 

208-460v

3, 4w

50/60 Hz

 

APPROX. WEIGHT (UNCRATED)

1,650 lbs.

 

 

 

748.4 kg

 

APPROX. WEIGHT (CRATED)

1,875 lbs.

 

 

 

850.5 kg

Steam

HEAT INPUT

 

 

 

13 Bhp

 

 

STEAM CONSUMPTION

450 lbs./hr

 

 

 

202.2 kg/hr

 

AIRFLOW

2,150 cfm

 

 

 

60.88 cmm

 

SUPPLY CONNECTION

 

 

 

1-1/4”

 

 

 

RETURN CONNECTION

 

 

 

1-1/4”

 

 

 

COMPRESSED AIR CONNECTION

 

 

 

1/8” N.P.T.

 

 

 

COMPRESSED AIR VOLUME

0.75 cfh

 

 

 

0.02 cmh

Shaded areas are stated in metric equivalents

IMPORTANT: Steam dryers must be provided with a clean, dry, and regulated 80 PSI +/- 10 PSI (5.51 bars +/- 0.68 bars) air supply.

NOTE: ADC reserves the right to make changes in specifications at anytime without notice or obligation

6

Image 10
Contents ML-130 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Page This Exhaust Duct Transition Piece Must be Installed First Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Downstream of Dryer Page Page Page Electrical Information ML-130 II Reversing, 3ø GAS ML-130 II Reversing, 3ø Steam MLE-130 II 72 Kw Electric Reversing, 3ø MLE-130 II 80 Kw Electric Reversing, 3ø Page Page GAS Information Type of GAS Page Page Operating Steam Pressure Steam InformationPage Bars Page Preparation for Operation Preoperational Tests Basket Coating Shut Down Instructions Operating InstructionsPage Service SERVICE/PARTS InformationParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Cleaning Routine MaintenanceSuggested Cleaning Schedule Steam Dryers Adjustments LubricationData Label Information Data LabelSerial Number Reversing Timer SPIN/DWELL Adjustments Timing LegendProcedure for Functional Check Replacement Components Page Page P O R T a N T For Timer or Phase 5 Without Heat Fault ADC 113314 1- 06/21/01-25