Amana W10150612A installation instructions Electrical Requirements U.S.A, Installation Clearances

Page 3

Installation Clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

Companion appliance spacing should also be considered.

 

3"*

14" max.*

(7.6 cm)

48 in.2 *

(35.6cm)

18"*

(310 cm2 )

 

(45.7 cm)

 

43³⁄₈"

(110cm)

*26" (66cm)

43³⁄₈"

(110cm)

*27¾"

(70.5cm)

15¼"

(38.74cm) 43³⁄₈" (110cm)

*27¾"

(70.5cm)

29"

(73.66cm)

A

22¾"

(57.8cm) 43³⁄₈"

(110cm)

*27¾"

(70.5cm)

29"

(73.66cm)

C

22¾"

(57.8cm)

29"

(73.66cm)

B

13¾" (34.9cm)

29"

(73.66cm)

D

 

 

 

 

 

24 in.2 *

3"*

 

 

 

 

 

(155 cm2 )

(7.6 cm)

1"

29"

1"

1"*

27¾"

5"*

 

(2.5 cm)

(73.66 cm)

(2.5 cm)

(2.5 cm)

(70.5 cm)

(12.7 cm)

 

 

A

 

 

B

 

C

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Required spacing

Mobile Home - Additional Installation Requirements

This dryer is suitable for mobile home installations.

The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or the Canadian Manufactured Home Standard, CAN/CSA-Z240 MH.

Mobile home installations require:

Metal exhaust system hardware, which is available for

purchase from your dealer.

A. Small opening side-swing door

B. Large opening side-swing door

C. Wide opening side-swing door

D. Wide opening hamper door

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Special provisions must be made in mobile homes to

introduce outside air into the dryer. The opening (such as a

nearby window) should be at least twice as large as the dryer

exhaust opening.

Electrical Requirements - U.S.A.

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

3

Image 3
Contents 29 73.7 CM Electric Dryer Installation Instructions Parts needed Tools and PartsLocation Requirements Parts suppliedIt is your responsibility Installation ClearancesMobile Home Additional Installation Requirements Electrical Requirements U.S.AIf connecting by direct wire Electrical ConnectionIf your outlet looks like this Canada Electrical Requirements CanadaElectrical Connection U.S.A. Only Power Supply Cord Direct WireInstall strain relief Style 1 Power supply cord strain reliefStyle 2 Direct wire strain relief Wire connection Power Supply CordRemove center silver-colored terminal block screw Wire connection Direct WireBDE CG F Optional 3-wire connection If using an existing vent system Venting RequirementsIf this is a new vent system Vent material Special provisions for mobile home installations Plan Vent SystemDetermine vent path Level Dryer Install Vent SystemInstall Leveling Legs Vent system chartReverse Door Swing Optional Reversible Large Side-Swing DoorReversible Super Wide Side-Swing Door If the dryer will not start, check the following Complete InstallationU.S.A CanadaOutillage et pièces Pièces fourniesPièces nécessaires On a besoin de Exigences d’emplacementDimensions de la sécheuse Dégagements de séparation à respecter’installation dans une maison mobile exige Spécifications électriques- Canada’est à l’utilisateur qu’incombe la responsabilité de En cas dutilisation du système dévacuation existant Exigences concernant lévacuationLe clapet incliné de type boîte ci-dessous est acceptable Planification du système d’évacuationUne réduction de la longévité de la sécheuse Installation du système d’évacuationInstallation des pieds de nivellement Déterminer litinéraire dacheminement du conduitGrande porte réversible à pivotement latéral Mise à niveau de la sécheuseRaccordement du conduit d’évacuation Inversion du sens douverture de la porte FacultatifSi la sécheuse ne démarre pas, vérifier ce qui suit Achever l’installationTous droits réservés W10150612A SP PN W10150613A