Amana W10150612A installation instructions Optional 3-wire connection

Page 10

1.Loosen or remove center silver-colored terminal block screw.

2.Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.

BC

D

AE

A. Neutral ground wire

B. External ground conductor screw

C. Center silver-colored terminal block screw

D. Neutral wire (white or center wire)

E. ³⁄₄" (1.9 cm) UL listed strain relief

3.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

4.Tighten strain relief screw.

5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

6.You have completed your electrical connections. Now go to “Venting Requirements.”

Optional 3-wire connection

Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw. Tighten screw.

A B C

D

E

F

A. External ground conductor screw B. Neutral ground wire

C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)

E. ¾" (1.9 cm) UL listed strain relief

F. Grounding path determined by a qualified electrician

3.Connect the other wires to outer terminal block screws. Tighten screws.

4.Tighten strain relief screws.

5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

6.Connect a separate copper ground wire from the external ground conductor screw to an adequate ground.

10

Image 10
Contents 29 73.7 CM Electric Dryer Installation Instructions Parts supplied Tools and PartsLocation Requirements Parts neededElectrical Requirements U.S.A Installation ClearancesMobile Home Additional Installation Requirements It is your responsibilityElectrical Connection If connecting by direct wireIf your outlet looks like this Electrical Requirements Canada CanadaStyle 1 Power supply cord strain relief Power Supply Cord Direct WireInstall strain relief Electrical Connection U.S.A. OnlyWire connection Power Supply Cord Style 2 Direct wire strain reliefWire connection Direct Wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection Venting Requirements If using an existing vent systemIf this is a new vent system Vent material Plan Vent System Special provisions for mobile home installationsDetermine vent path Vent system chart Install Vent SystemInstall Leveling Legs Level DryerReversible Large Side-Swing Door Reverse Door Swing OptionalReversible Super Wide Side-Swing Door Canada Complete InstallationU.S.A If the dryer will not start, check the followingPièces fournies Outillage et piècesPièces nécessaires Dégagements de séparation à respecter Exigences d’emplacementDimensions de la sécheuse On a besoin deSpécifications électriques- Canada ’installation dans une maison mobile exige’est à l’utilisateur qu’incombe la responsabilité de Exigences concernant lévacuation En cas dutilisation du système dévacuation existantPlanification du système d’évacuation Le clapet incliné de type boîte ci-dessous est acceptableDéterminer litinéraire dacheminement du conduit Installation du système d’évacuationInstallation des pieds de nivellement Une réduction de la longévité de la sécheuseInversion du sens douverture de la porte Facultatif Mise à niveau de la sécheuseRaccordement du conduit d’évacuation Grande porte réversible à pivotement latéralAchever l’installation Si la sécheuse ne démarre pas, vérifier ce qui suitW10150612A SP PN W10150613A Tous droits réservés