Amana W10150612A installation instructions Venting Requirements, If using an existing vent system

Page 11

Venting Requirements

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for cleaning.

Flexible metal vent must be fully extended and supported when the dryer is in its final location.

Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

Elbows

45° elbows provide better airflow than 90° elbows.

GoodBetter

Clamps

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.

Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance.

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape.

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended.

4"

10.2 cm

4" (10.2 cm) heavy metal exhaust vent

DURASAFE™ vent products can be purchased from your dealer or by calling the toll-free number listed on the cover of the Dryer User Instructions. For more information, see the “Assistance or Service” section of the Dryer User Instructions.

Rigid metal vent

Clamp

Exhaust

Recommended hood styles are shown here.

B

A

4"

(10.2 cm)

4" (10.2 cm)

A. Louvered hood style

B. Box hood style

The angled hood style (shown here) is acceptable.

4"

(10.2 cm)

For best drying performance, rigid metal vents are recommended.

Rigid metal vent is recommended to avoid crushing and kinking.

2½" (6.4 cm)

11

Image 11
Contents 29 73.7 CM Electric Dryer Installation Instructions Parts needed Tools and PartsLocation Requirements Parts suppliedIt is your responsibility Installation ClearancesMobile Home Additional Installation Requirements Electrical Requirements U.S.AIf your outlet looks like this If connecting by direct wireElectrical Connection Canada Electrical Requirements CanadaElectrical Connection U.S.A. Only Power Supply Cord Direct WireInstall strain relief Style 1 Power supply cord strain reliefStyle 2 Direct wire strain relief Wire connection Power Supply CordRemove center silver-colored terminal block screw Wire connection Direct WireBDE CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemVenting Requirements Determine vent path Special provisions for mobile home installationsPlan Vent System Level Dryer Install Vent SystemInstall Leveling Legs Vent system chartReversible Super Wide Side-Swing Door Reverse Door Swing OptionalReversible Large Side-Swing Door If the dryer will not start, check the following Complete InstallationU.S.A CanadaPièces nécessaires Outillage et piècesPièces fournies On a besoin de Exigences d’emplacementDimensions de la sécheuse Dégagements de séparation à respecter’est à l’utilisateur qu’incombe la responsabilité de ’installation dans une maison mobile exigeSpécifications électriques- Canada En cas dutilisation du système dévacuation existant Exigences concernant lévacuationLe clapet incliné de type boîte ci-dessous est acceptable Planification du système d’évacuationUne réduction de la longévité de la sécheuse Installation du système d’évacuationInstallation des pieds de nivellement Déterminer litinéraire dacheminement du conduitGrande porte réversible à pivotement latéral Mise à niveau de la sécheuseRaccordement du conduit d’évacuation Inversion du sens douverture de la porte FacultatifSi la sécheuse ne démarre pas, vérifier ce qui suit Achever l’installationTous droits réservés W10150612A SP PN W10150613A