Amana W10150612A Wire connection Direct Wire, Remove center silver-colored terminal block screw

Page 8

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver- colored terminal block screw. Tighten screw.

A B C

E

D

A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.

B. Center silver-colored terminal block screw C. Neutral wire (white or center wire)

D. ¾" (1.9 cm) UL listed strain relief E. Neutral ground wire

3.Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.

A B C

F E

D

A. External ground conductor screw

B. Center silver-colored terminal block screw

C. Neutral wire (white or center wire)

D. ¾" (1.9 cm) UL listed strain relief

E. Ground wire (green or bare) of power supply cord

F. Neutral ground wire

4.Connect the other wires to outer terminal block screws. Tighten screws.

5.Tighten strain relief screws.

6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

7.You have completed your electrical connections. Now go to “Venting Requirements.”

4-wire connection: Direct Wire

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.

Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5" (12.7 cm). Cut 1¹⁄₂" (3.8 cm) from

3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.

" 1 .5cm) (2

5"

(12.7

cm)

 

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.

A B

C

E

D

A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.

B. Center silver-colored terminal block screw C. Neutral wire (white or center wire)

D. ¾" (1.9 cm) UL listed strain relief E. Neutral ground wire

8

Image 8
Contents 29 73.7 CM Electric Dryer Installation Instructions Tools and Parts Location RequirementsParts supplied Parts neededInstallation Clearances Mobile Home Additional Installation RequirementsElectrical Requirements U.S.A It is your responsibilityIf your outlet looks like this If connecting by direct wireElectrical Connection Electrical Requirements Canada CanadaPower Supply Cord Direct Wire Install strain reliefStyle 1 Power supply cord strain relief Electrical Connection U.S.A. OnlyWire connection Power Supply Cord Style 2 Direct wire strain reliefWire connection Direct Wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemVenting Requirements Determine vent path Special provisions for mobile home installationsPlan Vent System Install Vent System Install Leveling LegsVent system chart Level DryerReversible Super Wide Side-Swing Door Reverse Door Swing OptionalReversible Large Side-Swing Door Complete Installation U.S.ACanada If the dryer will not start, check the followingPièces nécessaires Outillage et piècesPièces fournies Exigences d’emplacement Dimensions de la sécheuseDégagements de séparation à respecter On a besoin de’est à l’utilisateur qu’incombe la responsabilité de ’installation dans une maison mobile exigeSpécifications électriques- Canada Exigences concernant lévacuation En cas dutilisation du système dévacuation existantPlanification du système d’évacuation Le clapet incliné de type boîte ci-dessous est acceptableInstallation du système d’évacuation Installation des pieds de nivellementDéterminer litinéraire dacheminement du conduit Une réduction de la longévité de la sécheuseMise à niveau de la sécheuse Raccordement du conduit d’évacuationInversion du sens douverture de la porte Facultatif Grande porte réversible à pivotement latéralAchever l’installation Si la sécheuse ne démarre pas, vérifier ce qui suitW10150612A SP PN W10150613A Tous droits réservés