American Dryer Corp MLG-460 manual Possible Solutions

Page 63

3a) Malfunctioning operator interface terminal or communications cable.

4a) Malfunctioning 24 volt DC power supply.

5a) Malfunctioning hi-limit temperature controller.

b.POSSIBLE SOLUTIONS;

1b) Verify that fuses 7, 8, 9, and 10 are good.

Check that ALL fuse holder L.E.D. (light emitting diode) indicators are not lit.

If ALL fuses are good, go to paragraph #2b below, paragraph #3b below, paragraph #4b below, or paragraph #5b below and on page 60.

If a fuse is bad, check the corresponding circuit, replace the fuse and test.

2b) Malfunctioning PLC (Programmable Logic Controller).

If PLC power is off, a “LINE FAULT MESSAGE” will be displayed on the operator interface terminal.

NOTE: Call the ADC Service Department at (508) 678-9000.

3b) Malfunctioning operator interface terminal.

Check power supply voltage to the operator interface terminal. It should be 24 volts DC.

Check that the interface cable to both the PLC and the operator interface terminal are secure.

NOTE: Call the ADC Service Department at (508) 678-9000.

4b) Malfunctioning 24 volt DC power supply.

Verify that the power supply’s red “ON” light is illuminated.

Verify that 110 volt AC supply is available and correct.

Verify that the 4-40 mA (4-40 milliampere) transmitters or operator interface terminal are not causing the power supply to fail.

If the previous checked items are “OK,” replace the power supply.

5b) Malfunctioning hi-limit temperature controllers (HLS1 or HLS2).

HLS1 - exhaust temperature hi-limit

HLS2 - intake temperature hi-limit

HLS1 and HLS2 are monitored by a six (6) channel hi-limit temperature controller that once triggered must be manually reset.

59

Image 63
Contents MLG-460 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Service Parts Returning Warranty Cards Parts Returning Warranty PartsTroubleshooting TOC Section What to do if YOU Smell GAS Safety PrecautionsPage Specifications SpecificationsSpecifications Reassembly of Dryer Installation ProceduresPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsMLG-460 Page Fresh AIR Supply Requirements Preparation for Operation PRE START-UPCleaning Routine MaintenanceMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Compressed AIR System Page Page GAS Burner and Ignition System Switch #2 Intermittent Pilot Page Page Page Page Page Page Page Safety Devices Door Open Parts ServiceReturning Warranty Cards WarrantyReturning Warranty Parts Page Troubleshooting Power Malfunctions Possible SolutionsProbable Causes No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page Front Panel Blue Light and RED Light on Possible Solutions Unless the Water Valve to the Sprinkler is Closed General DescriptionBurner Section Input Circuit Component Description Burner Controller Input Signal ComponentsBurner Ignition IntroductionLoad Door Switch DS1B Stop Detector Relay Contact SMD no Output Signal Component DescriptionGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Components Tumbler Basket Section Electrical MalfunctionsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UP Unload 1 Selection Probable CausesDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Base Section Electrical Malfunctions Front Door SwitchRear Down Switch LS2 Lint Drawer Proximity SwitchesLint Chamber Pressure Switch PS3 Tumbler Basket Tilt Problems Level FaultProbable Solutions Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Electrical Components Pendant Control MalfunctionsVerify Pendant Electrical Signals ML-460 Pendant Assembly Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Motors Circuit Wiring to the Analog Input ModuleMotor Protection Device Descriptions Motor Actuation Problems Probable CausesAIR Fault Screen FaultMotor Fault GAS Fault