American Dryer Corp MLG-460 manual Heater Fault Message

Page 69

4b) To check “Interlock 2” (Heater Doors), verify that there is a 110 VAC signal on TB-41, on the Main Electrical Panel, when PLC (Programmable Logic Controller) output #4 is on.

NOTE: The heater door interlock switches are double-pole double-throw (DPDT). These switches affect different circuits.

If there is 110 VAC at the panel go to paragraph #5b below.

If there is not a signal, check circuit back to the burner door switches. Refer to the ML-460 Solenoid Junction Box Wiring Diagram for connection information.

5b) A quick way to check the load and unload door switches is to close the unload door (2-Door models) and toggle the load door’s “wobble arm,” and monitor INPUT #6 of the PLC (Programmable Logic Controller). Likewise, for 2-door models, close the load door and toggle the Unload door’s “wobble arm,” also monitor INPUT #7 of the PLC.

NOTE: The rotary arm switches mentioned are double-pole double-throw (DPDT), where the PLC (Programmable Logic Controller) signal and “door” switch effect different circuits.

If input #6 L.E.D. (light emitting diode) of the (Programmable Logic Controller) goes on and off, the signal is “good.” Go to Section #5 on page 69 and page 70.

If input #6 L.E.D. of the PLC doesn’t react, then perform the following

Power down the dryer.

Close the Load and Unload doors.

Check for continuity between TB1-70 and TB1-7 on the Main Electrical Panel Refer to the dryer Main Panel Wiring Diagram.

If no continuity, refer to the dryer Tumbler Junction Box Wiring diagram for detail information for door switch wiring.

6b) To check interlock 3 (PRS1 and PRS2), Gas pressure Hi/Lo switch:

Power down the dryer.

Check for continuity between TB1-18 and TB1-19.

If no continuity, refer to the dryer Solenoid Junction Box wiring diagram for detail information for PRS1 and PRS2 wiring.

4.“HEATER FAULT” Message

PLC (Programmable Logic Controller) MESSAGE - “HEATER FAULT”

a)PROBABLE CAUSES;

1a) Fuse 6.

65

Image 69
Contents MLG-460 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Service Parts Returning Warranty Cards Parts Returning Warranty PartsTroubleshooting TOC Section What to do if YOU Smell GAS Safety PrecautionsPage Specifications SpecificationsSpecifications Reassembly of Dryer Installation ProceduresPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsMLG-460 Page Fresh AIR Supply Requirements Preparation for Operation PRE START-UPCleaning Routine MaintenanceMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Compressed AIR System Page Page GAS Burner and Ignition System Switch #2 Intermittent Pilot Page Page Page Page Page Page Page Safety Devices Door Open Parts ServiceReturning Warranty Cards WarrantyReturning Warranty Parts Page Troubleshooting Power Malfunctions Possible SolutionsProbable Causes No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page Front Panel Blue Light and RED Light on Possible Solutions Unless the Water Valve to the Sprinkler is Closed General DescriptionBurner Ignition Burner Controller Input Signal ComponentsIntroduction Burner Section Input Circuit Component DescriptionLoad Door Switch DS1B Stop Detector Relay Contact SMD no Output Signal Component DescriptionGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Components Tumbler Basket Section Electrical MalfunctionsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UP Unload 1 Selection Probable CausesDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Rear Down Switch LS2 Front Door SwitchLint Drawer Proximity Switches Base Section Electrical MalfunctionsLint Chamber Pressure Switch PS3 Tumbler Basket Tilt Problems Level FaultProbable Solutions Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Electrical Components Pendant Control MalfunctionsVerify Pendant Electrical Signals ML-460 Pendant Assembly Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Motors Circuit Wiring to the Analog Input ModuleMotor Protection Device Descriptions Motor Actuation Problems Probable CausesMotor Fault Screen FaultGAS Fault AIR Fault