American Dryer Corp MLG-460 manual Door Open Problem

Page 83

5b) Input 19 L.E.D. (light emitting diode) is not illuminating correctly on the PLC (Programmable Logic Controller) indicates that the signal to the PLC input is missing or the PLC is defective.

Check FUSE 2 on the main electrical panel

Check wiring back to the tumbler junction box

Check wiring back to the rear controls

Check PLC (Programmable Logic Controller) Refer to wiring diagrams:

Main Electrical Panel Diagram

Tumbler Junction Box Wiring Diagram

Rear Panel Controls Wiring Diagram

Retest; verify that the signal is operational

5.”DOOR OPEN” Problem

A “DOOR OPEN” message is generated by either the heater, load, or unload doors. The following in- formation will address the load and unload doors signals, since they are associated with the tumbler junction box.

a)PROBABLE CAUSES;

1a) Wiring back to the PLC (Programmable Logic Controller).

DS1-B = LOAD DOOR SWITCH DS2-B = UNLOAD DOOR SWITCH

b)POSSIBLE SOLUTIONS;

1b) For quick check of LOAD and UNLOAD signals on the PLC (Programmable Logic Controller) perform the following:

Remove factory air from the dryer

With the Control Voltage “ON,” open the LOAD doors and locate the LOAD door switch actuator.

Cycle the switch by hand and have someone watch PLC input indicator #6. It should go “ON” when the switch is down.

Open the UNLOAD doors and locate the UNLOAD doors switch actuator.

Cycle the switch by hand and have someone watch PLC input indicator #7. It should go “ON” when the switch is down. Do the associated L.E.D.’s (light emitting diodes) come “ON” when the switch is down?

79

Image 83
Contents MLG-460 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Troubleshooting TOC Service PartsReturning Warranty Cards Parts Returning Warranty Parts Section What to do if YOU Smell GAS Safety PrecautionsPage Specifications SpecificationsSpecifications Reassembly of Dryer Installation ProceduresPage Page Location Requirements Internal AIR, Electric and Water Connections Page Page Page Page Page Left Drum Motor External Supply Connections Page Page Electrical Requirements Electrical RequirementsMLG-460 Page Fresh AIR Supply Requirements Preparation for Operation PRE START-UPCleaning Routine MaintenanceMonthly Component System Descriptions Page Page Main AIR Blower and Heat Reclaimer System Page Compressed AIR System Page Page GAS Burner and Ignition System Switch #2 Intermittent Pilot Page Page Page Page Page Page Page Safety Devices Door Open Parts ServiceReturning Warranty Parts Returning Warranty CardsWarranty Page Troubleshooting Probable Causes Power MalfunctionsPossible Solutions No Control Power Blue Light Off Machine Main Power Shuts Down Blue Indicator Off 2CRB Sprinkler Circuit Description Page Front Panel Blue Light and RED Light on Possible Solutions Unless the Water Valve to the Sprinkler is Closed General DescriptionBurner Section Input Circuit Component Description Burner Controller Input Signal ComponentsBurner Ignition IntroductionLoad Door Switch DS1B Stop Detector Relay Contact SMD no Output Signal Component DescriptionGAS Fault Message gas system only Heater Fault Message Possible Solutions Page Page AIR Fault Message HI-TEMP Fault Message Possible Solutions Drum Fault Message Page Tumbler Basket Section Electrical Components Tumbler Basket Section Electrical MalfunctionsFollowing is for 2-Door Models only Rear Panel Control Problems Probable Causes Possible Solutions PLC OUT PIN 7 = Unload Door Open PLC OUT PIN 10 = Front UP Unload 1 Selection Probable CausesDoor Open Problem Drum Fault Message Malfunction Probable Causes Page Base Section Electrical Malfunctions Front Door SwitchRear Down Switch LS2 Lint Drawer Proximity SwitchesProbable Solutions Lint Chamber Pressure Switch PS3Tumbler Basket Tilt Problems Level Fault Page Lint Screen Mechanism Problem Screen Fault Lint Chamber Air Pressure Problem AIR Fault Pendant Electrical Components Pendant Control MalfunctionsVerify Pendant Electrical Signals ML-460 Pendant Assembly Diagram Temperature Sensing Page Temperature Measurement and Sensing Problems Motors Circuit Wiring to the Analog Input ModuleMotor Protection Device Descriptions Motor Actuation Problems Probable CausesAIR Fault Screen FaultMotor Fault GAS Fault