4.Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements in Section D).

5.Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

6.Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

7.The dryer must be installed with a proper exhaust duct connection to the outside as noted in this manual (refer to Exhaust Requirements in Section E).

8.Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements in Section E).

IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.

9. The dryer must be installed with adequate clearance for air openings into the combustion chamber.

CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint buildup.

IMPORTANT: Dryer must be installed in a location/environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C).

C. DRYER ENCLOSURE REQUIREMENTS

Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.48 cm) above the dryer’s outer top; except along the front of the dryer, which may be closed if desired.

NOTE: Allowances must be made for opening the control door.

NOTE: With the exception of the floor, clearances shown are for combustible construction.

X= 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease of maintenance. * Not applicable.

** A minimum of 12-inches (30.48 cm) above the dryer’s outer top; except along the front of the dryer, which may be closed if desired.

113307 - 7

Maytag Co.

7

Image 11
Contents MDG30PNH / MDG30MNV Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Safety PrecautionsStandards 13.6 kg SpecificationsSpecifications Location Requirements Installation ProceduresUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Multiple Dryer Common Venting Electrical Requirements Electrical InformationService Phase Wire Approx Circuit AMP Draw Single-Phase Electrical Lead Connections GAS Information Type of GAS Maytag Co Preparation for OPERATION/START-UP GAS Models only Preoperational TestsPreoperational Instructions Dual Timer DryersShutdown Instructions Reversing Timer SPIN/DWELL AdjustmentsParts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Suggested Cleaning Schedule Routine MaintenanceCleaning Lubrication AdjustmentsData Label Information Procedure for Functional Check Replacement Components Maytag Co 113307 Fire Suppression System Fire Suppression System In ActionWater Connections InstallationTypical Water Supply 06/26/08