NOTE: A water column test pressure of 3.5 inches (8.7 mb) for natural gas and 10.5 inches (26.1 mb) for liquid propane (L.P.) dryers is required at the gas valve pressure tap of each dryer for proper and safe operation.
A 1/8” N.P.T. plugged tap, accessible for a test gauge connection, must be installed in the main gas supply line immediately upstream of each dryer.
IMPORTANT: Pipe joint compounds that resist the action of natural gas and L.P. gas must be used.
IMPORTANT: Test ALL connections for leaks by brushing on a soapy water solution (liquid detergent works well).
WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!
IMPORTANT: The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
NOTE: The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure test of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
H. PREPARATION FOR OPERATION/START-UP
The following items should be checked before attempting to operate the dryer:
1.Read ALL “CAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.
2.Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label.
3.GAS MODELS – check to ensure that the dryer is connected to the type of gas indicated on the dryer data label.
4.GAS MODELS – the sail switch damper assembly was installed and adjusted at the factory prior to shipping. However, each sail switch adjustment must be checked to ensure that this important safety control is functioning.
5.Check bolts, nuts, screws, terminals, and fittings for tightness and security.
6.GAS MODELS – be sure that ALL gas shutoff valves are in the open position.
7.Check that ALL back guard panels and service box covers have been replaced.
8.Check the lint door/drawer to ensure that it is closed and secured in place.
9.Rotate the basket (tumbler/drum) by hand to be sure it moves freely.
10.Check basket (tumbler) bearing setscrews to ensure that they are ALL tight.
11.Check vent is connected to the dryer and is exhausted to the outdoors.