Maytag MDG30PNH, MDG30MNV installation manual Type of GAS

Page 20

2.Technical Gas Data a. Gas Specifications

 

TYPE OF GAS

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

 

 

 

 

 

Shaded areas are stated in metric equivalents

*Measured at outlet side of gas valve pressure tap when gas valve is on.

b. Gas Connections

 

Inlet connection

1/2” N.P.T.

Inlet supply size

1/2” Diameter Pipe (minimum)

Heat input (per dryer)

100,000 Btu/hr (25,200 kcal/hr)

1) Natural Gas

 

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

TYPE OF GAS

 

Liquid

 

 

 

 

 

 

 

 

 

Propane

Btu

 

 

Natural

 

 

Liquid Propane

kcal/hr

 

 

 

Conversion Kit

Per Hour

Qty.

D.M.S.*

 

Part

Qty.

D.M.S.*

Part

Rating

Rating

 

Number

Number

Part Number

 

 

 

 

 

 

 

100,000

25,200

2

#29

 

140820

2

#46

140806

883321

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#29 = 0.1360” (3.4540 mm).

Liquid Propane Gas

#46 = 0.810” (2.0574 mm).

16

Maytag Co.

113307 - 7

Image 20
Contents MDG30PNH / MDG30MNV Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Safety Precautions SectionStandards Specifications 13.6 kgSpecifications Location Requirements Installation ProceduresUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Multiple Dryer Common Venting Electrical Information Electrical Requirements Service Phase Wire Approx Circuit AMP Draw Single-Phase Electrical Lead Connections GAS Information Type of GAS Maytag Co Preparation for OPERATION/START-UP Preoperational Tests GAS Models onlyDual Timer Dryers Preoperational InstructionsReversing Timer SPIN/DWELL Adjustments Shutdown InstructionsParts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Suggested Cleaning Schedule Routine MaintenanceCleaning Adjustments LubricationData Label Information Procedure for Functional Check Replacement Components Maytag Co 113307 Fire Suppression System In Action Fire Suppression SystemInstallation Water ConnectionsTypical Water Supply 06/26/08