PROBLEM
CHECK POINT |
| CAUSE |
|
|
|
SOLUTION
Does the water supply continue while the power is turned off?
NO
Does the water supply start as soon as you press the power switch?
NO
YES
YES
The water inlet valve is defective.
The triac of P.C.B is defective.
Change the water inlet valve.
Change the P.C.B ASS’Y.
WATER SUP-
PLY IS NOT
STOPPED.
Operate the washer after setting the water level to “HIGH”
Does the water supply continue after the water reaches to the “HIGH” level?
YES
Is the air tube of water level switch kinked or deformed?
NO
Normal operation.
YES |
|
|
|
| |
Air tube is defective. |
|
| Change the air tube. | ||
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
NO | Pressure switch is defec- |
|
| Change the pressure | |
tive. |
|
| switch. | ||
|
|
|
| ||
|
|
|
|
|
|
CONCERNING WASHING
PROBLEM |
| CHECK POINT |
| CAUSE |
| SOLUTION |
|
|
|
|
|
|
|
Does the motor operate after fin- ishing water supply?
NO | YES |
|
Does pulsator rotate in | YES | |
only one direction? |
|
The triac of P.C.B is defective.
NO
Change the P.C.B ASS’Y.
Normal
THE PUL-
SATOR DOES
NOT ROTATE
EVEN IF THE
WATER IS
SUPPLED.
Does the motor make operating sound?
YES |
| NO | YES |
|
|
|
| |||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| ||
| Is the | motor coil dis- | Motor is defective. |
|
| Change the motor. | ||||
|
|
|
|
|
|
|
|
| ||
| connected? |
|
|
|
| |||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Is the connection condi- | NO | Improper connection | ||
tion of capacitor termi- |
|
| ||
|
|
| ||
nal good? |
|
|
| |
|
|
|
|
|
| YES | YES | ||
| ||||
|
|
Is the |
|
| ||
|
|
|
| |
NO |
|
|
|
|
|
|
|
Connect the terminal properly.
Change the
Change the motor.
26TROUBLE SHOOTING