Maytag MLG32PDA manual Location of the Dryer

Page 13

B.LOCATION OF THE DRYER

Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1-LATEST EDITION, or in CANADA, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION.

1.The dryer must be installed on a sound level floor capable of supporting its weight. It is recommended that carpeting be removed from the floor area that the dryer is to rest on.

2.The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

3.The dryer is for use in noncombustible locations.

4.Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply in Section D).

5.Clearance provisions must be made from non-combustible construction as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

Even though a 12-inch clearance is acceptable, it is recommended that the rear of the dryer be positioned approximately 2 feet away from the nearest obstruction, i.e., wall, for ease of installation, maintenance, and service. (Refer to the illustration on page 12.)

6.Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

7.Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements in Section E).

8.Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements in Section E).

IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.

9

Image 13
Contents What do YOU do if YOU Smell GAS MLG32PDARetain This Manual In a Safe Place For Future Reference Page For Your Safety Table of Contents Routine Maintenance Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsCan Create a Fire Hazard Specifications MLG32PDA UNPACKING/SETTING UP Installation ProceduresLocation of the Dryer Fresh AIR Supply Dryer Enclosure RequirementsPage Single Dryer Venting Exhaust RequirementsPage Page Page Electrical Information Page 120 GAS Information Type of GAS Page Preoperational Tests Preparation for OperationGas Inches Water Column Shut Down Instructions Starting the Dryer Operating InstructionsService SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Cleaning Routine MaintenanceDays Lubrication AdjustmentsPart No 1 01/13/98-500 2* 05/06/98-500 05/19/98-500