3)Start the dryer by pressing the desired fabric setting. After the cycle is started, drying time will count down whether the door is closed or open.

NOTE: The dryer can be stopped at any time by opening the main door. To restart dryer, shut the main door and press desired fabric setting.

4)Open main door to stop the dryer, and change to a different fabric setting. Repeat this procedure, until ALL fabric selections have been tested. This will also confirm that setting key circuits and door switch circuits are functioning properly.

5)Repeat above procedure for the other basket (tumbler).

2.Heat Circuit Operational Test.

a.When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.

NOTE: During the purging period, check to be sure that ALL gas shut-off valves are open.

NOTE: Gas dryers are equipped with a Hot Surface Ignition (HSI) system which has internal diagnostics. If ignition is not established after the first attempt, the heat circuit in the DSI module will lock out until it is manually reset. To reset the DSI system, open and close the main door and restart the dryer.

b.Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column pressure is correct and consistent.

NOTE: Water column pressure requirements (measured at the pressure tap of the gas valve body):

Natural Gas

4.0 Inches Water Column

L.P. Gas

11.0 Inches Water Column

IMPORTANT: THERE IS NO REGULATOR PROVIDED IN AN L.P. DRYER. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

23

Image 27
Contents What do YOU do if YOU Smell GAS MLG32PDARetain This Manual In a Safe Place For Future Reference Page For Your Safety Table of Contents Routine Maintenance Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsCan Create a Fire Hazard Specifications MLG32PDA UNPACKING/SETTING UP Installation ProceduresLocation of the Dryer Fresh AIR Supply Dryer Enclosure RequirementsPage Single Dryer Venting Exhaust RequirementsPage Page Page Electrical Information Page 120 GAS Information Type of GAS Page Preoperational Tests Preparation for OperationGas Inches Water Column Shut Down Instructions Starting the Dryer Operating InstructionsSERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsWarranty Cleaning Routine MaintenanceDays Lubrication AdjustmentsPart No 1 01/13/98-500 2* 05/06/98-500 05/19/98-500