3.Make a complete operational check of ALL the operating controls to insure that the timing is correct and that the temperatures are set properly.

4.Make a complete operational check of ALL safety-related circuits (i.e., door switches, hi-limit thermostats, sail switches, basket (tumbler) safety thermostats, etc.).

NOTE: The sail switch can be checked for proper operation by opening the control door while the dryer is running and the heating unit (burner) active (on). The heating unit(s) should shut off within a few seconds. If not, make the necessary adjustments.

5.Each basket (tumbler) should be operated through one (1) complete cycle to assure that no further adjustments are necessary and that ALL components are functioning properly.

IMPORTANT: The dryer baskets (tumblers) are treated with a protective coating. This coating can be removed by tumbling old clothes or material in the baskets (tumblers) using a mild detergent to remove the protective coating.

6.Computer Programs / Selections...

Each microprocessor controller (computer) has been preprogrammed by the factory with the most commonly used program (parameter) selections. If microprocessor controller (computer) program changes are required, refer to the computer programming manual which was shipped with the dryer.

J.SHUT DOWN INSTRUCTIONS

In the case where the dryer is to be shut down (taken out of service) for a period of time, the following MUST BE performed:

1.Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2.Discontinue the gas supply (for GAS MODELS ONLY):

1)SHUT OFF external gas supply shut-off valve (for both the top basket [tumbler] and the bottom basket [tumbler] where the independent supply line for each basket [tumbler] is used).

2)SHUT OFF internal gas supply shut-off valve located in the gas valve burner area (for both the top basket [tumbler] and the bottom basket [tumbler]).

24

Image 28
Contents MLG32PDA What do YOU do if YOU Smell GASRetain This Manual In a Safe Place For Future Reference Page For Your Safety Table of Contents Routine Maintenance Section Important InformationSafety Precautions What to do if YOU Smell GASCan Create a Fire Hazard Specifications MLG32PDA Installation Procedures UNPACKING/SETTING UPLocation of the Dryer Dryer Enclosure Requirements Fresh AIR SupplyPage Exhaust Requirements Single Dryer VentingPage Page Page Electrical Information Page 120 GAS Information Type of GAS Page Preparation for Operation Preoperational TestsGas Inches Water Column Shut Down Instructions Operating Instructions Starting the DryerService SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Routine Maintenance CleaningDays Adjustments LubricationPart No 1 01/13/98-500 2* 05/06/98-500 05/19/98-500