Maytag W10443046B-SP, W10443045B Electric Dryer Power Hookup Canada only, Electrical Requirements

Page 7

Closet Installation (stacked washer and dryer):

6"

(152 mm)

ELECTRIC DRYER

POWER HOOKUP – CANADA ONLY

ELECTRICAL REQUIREMENTS

3"

(76 mm)

71"

(1803 mm)

51/2"

(140 mm)

3"

(76 mm)

1"

1"

(25 mm)

(25 mm)

 

48in.2

(310 cm2)

24in.2

(155 cm2)

It is your responsibility:

■■ To contact a qualified electrical installer.

Custom under counter installation (dryer only):

■■ To be sure that the electrical connection is adequate and in conformance with Canadian Electrical Code, C22.1 – latest edition and all local codes. A copy of above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

1" (25 mm)

39" min.

(990 mm)

1"

(25 mm)

■■ To supply the required 4-wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

■■ This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard

14-30R wall receptacle. The cord is 5 ft.

(1.52 m) long. Be sure wall receptacle is

NOTE: Some models not recommended for undercounter installation.

Mobile home – Additional installation requirements:

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All dryers:

■■ Metal exhaust system hardware, available for purchase from your dealer. For further information, see “Assistance or Service” section in your Use and Care Guide.

■■ Special provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.

For gas dryers mobile home installations:

■■ Mobile Home Installation Hold-down Kit Part Number 346764 is available to order. For further information, see “Assistance or Service” section in your Use and Care Guide.

within reach of dryer’s final location. 4-wire receptacle (14-30R)

If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317.

For further information, please reference service numbers located in “Assistance or Service” section of your Use and Care Guide.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a quali•ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not •t the outlet, have a proper outlet installed by a quali•ed electrician.

SAVE THESE INSTRUCTIONS

7

Image 7
Contents Table of Contents Table des matières Dryer Safety Page Parts supplied steam models Installation Requirements Tools needed for all installations Parts supplied all modelsLocation Requirements Dryer DimensionsYou will need Cabinet installation dryer only Closet installation dryer onlySpacing for recessed area or closet installation Electrical Requirements Electric Dryer Power Hookup Canada onlyLP Gas Conversion GAS Dryer Power HookupGAS Supply Requirements GAS TypeBurner Input Requirements Gas supply pressure testingGAS Supply Line GAS Supply Connection RequirementsVenting Plan Vent System Recommended exhaust installationsAlternate installations for close clearances Optional exhaust installationsConnect vent to exhaust hood Install Vent SystemInstall Leveling Legs Install exhaust hoodConnect Inlet Hoses Make GAS ConnectionAttach long hose to Y connector and tighten couplings Attach short hose and Y connectorAttach long hose to dryer fill valve and tighten coupling Level Dryer Connect VentDoor Reversal Complete Installation ChecklistTroubleshooting Adjust leveling legsSécurité DE LA Sécheuse QUE Faire Dans LE CAS D’UNE Odeur DE GAZ Pièces fournies tous les modèles Exigences D’INSTALLATIONPièces fournies modèles à vapeur Vue porte ouverte Exigences D’EMPLACEMENTDimensions DE LA Sécheuse Il vous faudraInstallation dans un encastrement sécheuse Installation dans un placard sécheuseSeulement Toutes les sécheuses Installation sous comptoir personnalisée sécheuse seulementSpécifications Électriques ’est à l’utilisateur qu’incombe la responsabilité deType DE GAZ Raccordement D’UNE Sécheuse À GAZInstructions DE Liaison À LA Terre Conservez CES InstructionsCanalisation D’ARRIVÉE DE GAZ DE LA Sécheuse Canalisation DE GAZExigences Concernant LE Raccordement AU GAZ Caractéristiques D’ALIMENTATION DU BrûleurExigences Concernant L’ÉVACUATION ’ÉVACUATIONBrides de serrage Installations d’évacuations recommandéeAutres installations où le dégagement est réduit Planification DU Système D’ÉVACUATIONDispositions spéciales pour les maisons mobiles Installations d’evacuation facultativesTableau des systèmes d’évacuation standard Tableau des systèmes d’évacuation longuesInstallation DES Pieds DE Nivellement Installation DU Circuit D’ÉVACUATIONFermer l’eau froide retirer et Raccordement AU GAZRaccordement DU Tuyau D’ARRIVÉE D’EAU Raccorder l’alimentation en gaz à la sécheuseSerrer les raccords Fixer le tuyau court et le raccord en YFixer le long tuyau au raccord en Y et serrer les raccords Réglage DE L’APLOMB DE LA Sécheuse Raccordement DU Conduit D’ÉVACUATIONDépannage Achever L’INSTALLATION Liste DE VérificationInversion DE LA Porte Laveuse ET Sécheuse Superposées