71#DOLJQPHQW#DQG#DGMXVWPHQWV
7041#Huuru#lwhpv#dqg#Gldjqrvwlf#Frghv
1.An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.
Display | Description | Trigger | Action Taken | |
|
|
| Check for: | |
|
| The Thermistor | - Clogged lint screen. | |
| Dryer Thermistor Short | - Restricted vent sys- | ||
tS | resistance is | |||
Sensed | tem. | |||
| very low. | |||
|
| - Check Thermistor | ||
|
|
| ||
|
|
| resistance. | |
|
|
| Check for: | |
|
| The Thermistor | - Clogged lint screen. | |
| Dryer Thermistor Open | - Restricted vent sys- | ||
tO | resistance is | |||
Sensed | tem. | |||
| very high. | |||
|
| - Check Thermistor | ||
|
|
| ||
|
|
| resistance. | |
|
|
| Check for: | |
|
| Running the | - Close the door, and | |
|
| run the dryer | ||
do | Door Open | dryer with door | ||
- Loose or open wire | ||||
|
| open | ||
|
| terminals in Door | ||
|
|
| ||
|
|
| Sense circuit. | |
|
|
| Check for: | |
|
| Invalid power | - Not using regular | |
| Power source frequen- | power source | ||
FE | source | |||
cy Error | frequency | |||
| Frequency | |||
|
| - Invalid power fre- | ||
|
|
| ||
|
|
| quency sense circuit | |
|
| Invalid state for more | Check for: | |
|
| - Loose or open wire | ||
dF | Door Circuit Failure | than 256 | ||
terminals in Door | ||||
|
| milliseconds | ||
|
| Sense circuit. | ||
|
|
| ||
|
|
| Check for: | |
|
| Invalid heating Temp in | - Restricted vent sys- | |
hE | Heater Error | tem. | ||
running the dryer | ||||
|
| - Check Thermistor | ||
|
|
| ||
|
|
| resistance. | |
|
| Invalid state | Check for: | |
bE | Button Error | of key circuit short | - Display PCB key | |
|
| for 75secs | circuit short or not | |
|
| Invalid Dry | Check for: | |
|
| - Sensor bar Open | ||
od | Over Dry | time in | ||
- using Adjust time Up | ||||
|
| excess Dry time | ||
|
| excessively | ||
|
|
| ||
|
| Invalid state | Check for | |
Et | EEprom Fail | of Eeprom | - PCB on EEprom | |
|
| communication | circuit |