Humminbird MATRIX 12, MATRIX 37, Matrix 20, MATRIX 17, Matrix 27 Sonar Zoom View, Full range view

Page 7

wwwReal Time..reelschelSonar (RTS®) Windowmatic..com

A Real Time Sonar (RTS®) Window appears on the right side of the display in the Sonar View only. The RTS® Window always updates at the fastest rate possible for depth conditions and shows only the returns from the bottom, structure and fish that are within the transducer beam. The RTS® Window plots the depth and intensity of a sonar return (see Sonar Menu - RTS® Window).

Sonar Zoom View

Sonar Zoom View increases the displayed resolution to separate sonar returns that are very close together, such as those caused by fish suspended close to the bottom or within structure. In Zoom View, the display is split to show a narrow slice of the full range view on the right and the zoomed view on the left. The full range view on the right also contains the Zoom Preview Box that shows what part of the full range view is shown in zoom view on the left; the Zoom Preview Box tracks the bottom in

The Narrow RTS® Window indicates the sonar intensity through the use of grayscale. The grayscale used matches the bottom view grayscale setting used in the sonar history window (i.e. Inverse, StructureID®, WhiteLine®, Bottom Black). The depth of the sonar return is indicated by the vertical placement of the return on the display depth scale.

The Wide RTS® Window indicates the sonar intensity through the use of a bar graph. The length of the plotted return provides an indication of whether the return is weak or strong. The depth of the sonar return is indicated by the vertical placement of the return on the display depth scale. The Wide RTS® Window does not make use of grayscale.

the full range view.

As the depth changes, the zoomed view updates automatically to display a magnified image of the bottom. The Zoom Preview Box shows where the zoomed view is in relation to the full range view. The Zoom Level, or magnification, is displayed in the lower left corner and can be changed to suit conditions (see Sonar X-PressTMMenu: Zoom Level). Upper and Lower Zoom Depth Range numbers indicate the depth of the water which is being viewed.

Digital depth is displayed in the upper left hand corner. The digital readouts in the Sonar Zoom View cannot be customized; therefore, information such as water temperature and voltage are unavailable in the Sonar Zoom View.

Depth

Zoomed

View

Zoom Level

Sonar Zoom View

Upper Depth Range,

Full Range View

Upper Depth Range,

Zoom View

Full Range View

Zoom

Preview Box

Lower Depth Range,

Full Range View

Lower Depth

Range, Zoom View

7

8

Image 7
Contents Operations Manual WwwThank You!..reelschel matic..com Table of ContentsSonar Menu Tab Alarms Menu TabSetup Menu Tab Accessories Menu Tab TroubleshootingDualBeam Plus Sonar Single Beam SonarQuadraBeam Sonar Soft Bottom WwwWhat’s On..reelschelthe Disp ay matic..comBait Ball Hard BottomUnderstanding Sonar History Sonar ViewSonar View Full range view Sonar Zoom ViewSonar Zoom View Big Digits View Big Digits ViewDualBeam Plus and QuadraBeamTM Only 200/83 kHz Split Sonar ViewSide Beam View Bottom PresentationQuadraBeamTM Only Digital readouts in the Side Beam View cannot be customizedKey Functions POWER/LIGHT KeyView Key Exit Key WAY Cursor Control KeyPowering Up the Unit AccessorymBusaticMenu System Normal Operation Start-Up Options MenuPC Connect System StatusWith PC Connect Cable Only Upper Range To adjust the SensitivityTo adjust the Upper Range SensitivityTo adjust the Bottom View Chart SpeedTo adjust the Lower Range To adjust the Chart SpeedHighlight Zoom Level on the Sonar X-PressTMMenu To adjust the Zoom LevelSonar Menu Tab Sonar Zoom View OnlyTo turn Fish ID+ on or off Fish ID+TMTo use Beam Select Highlight Beam Select on the Sonar main menuKHz Sensitivity Real Time Sonar RTS WindowKHz Balance Advanced To change the Depth Lines settingTo change the Surface Clutter setting Surface ClutterWater Type Max DepthTransducer Select Alarm Tone Depth AlarmFish ID Alarm Low Battery AlarmUnits Temp Units DepthUnits Distance Language User ModeTriplog Reset Restore DefaultsAdvanced, Sonar View Only TemperatureSelect Readouts To Select ViewsTemp Offset To change the Depth Offset settingTo change the Temp Offset setting Depth OffsetAdvanced, with Temp/Speed Only Accessories Menu TabTo change the Speed Calibration setting Nmea OutputProblem Possible Cause Display ProblemsControl head loses power at high speeds Isolation Matrix Fishing System AccessoriesSpecifications Contact Humminbird
Related manuals
Manual 31 pages 15.56 Kb