MATERIAL SAFETY DATA SHEET

N/A = not applicable or not available

(To comply with 29 CFR 1910.1200)

SECTION 1 – PRODUCT IDENTIFICATION

Product Name: SOUNDSAFE®

Generic Name: Ultrasonic Couplant

Manufacturer: Sonotech, Inc.

774 Marine Dr., Bellingham, WA 98225

(360) 671-9121

SECTION 2 – HAZARDOUS INGREDIENTS

This material does not contain any ingredients having known health hazards in concentrations greater than 1%.

This material does not contain any known or suspected

carcinogens.

NFPA Hazardous Materials

Identification System (est)

Health……………………0

Flammability…………….0

Reactivity………………..0

SECTION 3 – PHYSICAL DATA

(nominal)

Boiling Point: >220°F

pH: 7.35 – 7.9

Freezing Point: <20°F

Acoustic Imp.: 1.726x106

Vapor Pressure: N/A

Vapor Density: N/A

Evaporation Rate: N/A

Specific Gravity: >1.02

Solubility in Water: complete

Appearance and Odor: water white, opaque gel; bland odor

SECTION 4 – FIRE AND EXPLOSION

SECTION 5 – REACTIVITY DATA

HAZARD DATA

 

Flash Point: none

Stability: Stable

Upper Exposure Limit: none

Conditions to Avoid: none

Lower Exposure Limit: none

Incompatibility (Materials to Avoid): none known

Special Fire Fighting Procedures: N/A

Hazardous Polymerization: will not occur

Extinguishing media: N/A

Hazardous Decomposition or Byproducts: none known

Unusual Fire and Explosion Hazards: none

 

SECTION 6 – HEALTH HAZARD AND FIRST AID DATA

Routes of Entry:1

 

Skin: not likely

Ingestion: not normally

Eyes: not normally

Inhalation: no

Effects of Overexposure: Acute: May cause temporary eye irritation

Chronic: none expected

First Aid Procedures:

Skin: Remove with water if desired.

Eyes: Flush with water for 15 minutes.

Ingestion: For large quantities, induce vomiting and call a physician.

Inhalation: N/A

SECTION 7 – STORAGE AND HANDLING

INFORMATION

Precautions to be taken in handling and storage: Store between 20°F and 120°F. Spills are slippery and should be cleaned up immediately.

Steps to be taken in case material is released or spilled: Pick up excess for disposal. Clean with water.

Waste disposal method: Dispose of in accordance with federal, state, and local regulations.

SECTION 8 – CONTROL MEASURES

Respiratory Protection: not required

Ventilation: not required

Protective Gloves: on individuals demonstrating sensitivity to SOUNDSAFE®

Eye Protection: as required by working conditions

Other Protective Equipment: not required

1SOUNDSAFE® contains only food grade and cosmetic grade ingredients.

SONOTECH, INC.

Toll Free: 1-800-458-4254

774 Marine Dr., Bellingham, WA 98225

Fax: (360) 671-9024

Telephone: (360) 671-9121

Image 40
Contents P-114-0002 Page Contents DisclaimerBlank Introduction Blank Operation KeypadDakota Ultrasonics MX-5 Ultrasonic Thickness Gauge Dakota Ultrasonics Display Dakota Ultrasonics Transducer Making Measurements MX-5 Ultrasonic Thickness Gauge Condition and Preparation of Surfaces Probe Zero Performing a Probe-ZeroCalibration Calibration to a known thickness Calibration to a known velocity Two Point Calibration Scan Mode Moving series of dashes instead of a thickness value. WhenAlarm Mode Using the BeeperDifferential Mode RS232 Serial Port Connecting To a Computer Transducer Selection Dakota Ultrasonics MX-5 Ultrasonic Thickness Gauge Blank Product Specifications Physical Appendix aBlank Appendix B Application Notes ∙ Measuring pipe and tubing∙ Measuring laminated materials MX-5 Ultrasonic Thickness Gauge Blank Appendix C Sound Velocities of some Common MaterialsBlank Warranty Information ∙ Warranty Statement ∙SONOTECH, INC