Dakota Digital MX-5 operation manual Connecting To a Computer

Page 26

Dakota Ultrasonics

Connecting To a Computer

1)Connect the accessory cable (part# N-306-0010) to the 2 pin jack located on the bottom of the MX-5, and the 9 pin connector to a serial port on the computer.

2)Start the communications software that will be used to collect the measurements (i.e. Microsoft Windowsä 3.1 -Terminal, or 95 - HyperTerminal).

3)Setup the communications software using the following parameters: Data Bits - 8, Parity - None, Stop Bits - 1, Baud Rate 1200.

4)Set the communications software COMM port to the port number that the M X-5is connected.

5)After taking a measurement, press the SEND key to send the measurement to the computer. The measurement will be displayed on the computer screen.

NOTE: Communications software packages generally have the ability to capture the screen data to a common text file. This text file, containing the measurements, can then be imported into any common spreadsheet program (i.e. Excel, Quattro Pro, Lotus123) for further reporting requirements.

22

Image 26
Contents P-114-0002 Page Contents DisclaimerBlank Introduction Blank Operation KeypadDakota Ultrasonics MX-5 Ultrasonic Thickness Gauge Dakota Ultrasonics Display Dakota Ultrasonics Transducer Making Measurements MX-5 Ultrasonic Thickness Gauge Condition and Preparation of Surfaces Probe Zero Performing a Probe-ZeroCalibration Calibration to a known thickness Calibration to a known velocity Two Point Calibration Scan Mode Moving series of dashes instead of a thickness value. WhenAlarm Mode Using the BeeperDifferential Mode RS232 Serial Port Connecting To a Computer Transducer Selection Dakota Ultrasonics MX-5 Ultrasonic Thickness Gauge Blank Product Specifications Physical Appendix aBlank Appendix B Application Notes ∙ Measuring pipe and tubing∙ Measuring laminated materials MX-5 Ultrasonic Thickness Gauge Blank Appendix C Sound Velocities of some Common MaterialsBlank Warranty Information ∙ Warranty Statement ∙SONOTECH, INC