OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-DYN

TECHNICAL DATA

 

 

The following tables describe how the Channel Status Data bits are generated in the various con- version modes.

Output selected: Consumer format.

Input: Consumer format.

Output:All bits fed forward (transparent), except for:

Byte 1:Bits 0..6: 0000000 (category code general)

Bit 7: 1 (original)

Input: Professional format.

Output:

Byte 0:Bit 0: 0 (consumer)

Bit 1: 0 (audio)

Bit 2: 1 (copy allowed)

Bits 3,4: Preemphasis according to input

Bit 5: 0 (2 channel mode)

Bits 6,7: 00 (Mode 0)

Byte 1:Bits 0..6: 0000000 (category code general)

Bit 7: 1 (original)

Byte 2:Bits 0,1,2,3: Sampling Frequency according to input

Bits 4,5: 00 (accuaracy grade II)

Bits 6,7: 00

Bytes 3..23:

reserved bytes

Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster

 

Page 17 of 27

) +41 1 940 20 06 2 +41 1 940 22 14

8 http://www.weiss.ch

* weiss@weiss.ch

Image 17
Contents Gambit EQ1-DYN Contents Front Panel Front Panel Groups Introduction Remote ControlProcessing DisplayStatus Display OperationChannel Status Group Peak GroupDither Icon Snapshot DisplayRange What Is a Band?Band Parameters Controls Dynamic Correcting musical instrument volume imbalancesOn/Off SetupMode Comparison BackupRecall StoreLoading Backup will overwrite safe snapshots ResetDumping Dither Display Resolution LCD Contrast EQ BypassSelf Test Software InformationProtocol ChannelAES/EBU Input Technical DataAES/EBU Output AES/EBU Channel Status DataOutput selected Consumer format Output selected Professional format Filters PowerOverload Frequencies in Hertz Parameter TableBoost/Cuts, applicable to shelving and peaking filters Applicable to peaking filtersThreshold, applicable to dynamic peaking filters Shape, applicable to shelving filtersSlope, applicable to cut filters Overall GainDither Midi Implementation Remote Control ProtocolCH1 / 2 Select Byte Value Workspace and Settings request RS-422 RS-232