OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER | TECHNICAL DATA |
|
|
Dump Remote Control
All
Byte
1
2
3
4
5
6
Value
F0
00
30
5A
07
0000nnnn
Description
Sysex
Manufacturer's ID
Manufacturer's ID
Manufacturer's ID
Model ID: 6 = Gambit EQ DYN
Device ID:
Section
Header
Following is a list of the supported MIDI system exclusive commands (without header):
Snapshot format for dump. A complete dump consists of 128 snapshots:
| Byte |
| Value |
| Description |
| Section |
|
| ... |
| ... |
| Header | |
| 7 |
| 00000001 |
| message = Snapshot dump |
| Message Type |
| 8 |
| 0nnnnnnn |
| Package number ( 0..7F) |
| Data |
| 9 |
| 0nnnnnnn |
| scale set number |
|
|
| 10 - 265 |
| 0nnnnnnn |
| 256 Bytes of Snapshot data |
|
|
| 266 |
| 0ccccccc |
| Checksum without byte one (F0 Sysex Command) |
| Checksum |
| 267 |
| F7 |
| EOS |
| EOS |
Dump request: |
|
|
|
|
|
| |
| Byte |
| Value |
| Description |
| Section |
|
| ... |
| ... |
| Header | |
| 7 |
| 00000010 |
| message = dump request |
| Message Type |
| 8 |
| F7 |
| EOS |
| EOS |
Version request: |
|
|
|
|
|
| |
| Byte |
| Value |
| Description |
| Section |
|
| ... |
| ... |
| Header | |
| 7 |
| 00000011 |
| message = version request |
| Message Type |
| 8 |
| F7 |
| EOS |
| EOS |
Version send: |
|
|
|
|
|
| |
| Byte |
| Value |
| Description |
| Section |
7
8
9
... | ... | Header |
00000100 | message = send version | Message Type 4 |
0vvvvvvv | OS Version | data |
0vvvvvvv | DSP Version |
|
Daniel Weiss Engineering Ltd., Florastr. 42, |
| Page 25 of 27 |