Edelweiss EQ1-DYN manual Byte Value

Page 25

OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-DYN

TECHNICAL DATA

 

 

Dump Remote Control

All System-Exklusive commands consist of a header, a message type, possible data and the EOS (end of system exclusive). Below is the format of the header:

Byte

1

2

3

4

5

6

Value

F0

00

30

5A

07

0000nnnn

Description

Sysex

Manufacturer's ID

Manufacturer's ID

Manufacturer's ID

Model ID: 6 = Gambit EQ DYN

Device ID: -> Midi channel number

Section

Header

Following is a list of the supported MIDI system exclusive commands (without header):

Snapshot format for dump. A complete dump consists of 128 snapshots:

 

Byte

 

Value

 

Description

 

Section

 

1-6

 

...

 

...

 

Header

 

7

 

00000001

 

message = Snapshot dump

 

Message Type

 

8

 

0nnnnnnn

 

Package number ( 0..7F)

 

Data

 

9

 

0nnnnnnn

 

scale set number

 

 

 

10 - 265

 

0nnnnnnn

 

256 Bytes of Snapshot data

 

 

 

266

 

0ccccccc

 

Checksum without byte one (F0 Sysex Command)

 

Checksum

 

267

 

F7

 

EOS

 

EOS

Dump request:

 

 

 

 

 

 

 

Byte

 

Value

 

Description

 

Section

 

1-6

 

...

 

...

 

Header

 

7

 

00000010

 

message = dump request

 

Message Type

 

8

 

F7

 

EOS

 

EOS

Version request:

 

 

 

 

 

 

 

Byte

 

Value

 

Description

 

Section

 

1-6

 

...

 

...

 

Header

 

7

 

00000011

 

message = version request

 

Message Type

 

8

 

F7

 

EOS

 

EOS

Version send:

 

 

 

 

 

 

 

Byte

 

Value

 

Description

 

Section

1-6

7

8

9

...

...

Header

00000100

message = send version

Message Type 4

0vvvvvvv

OS Version

data

0vvvvvvv

DSP Version

 

Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster

 

Page 25 of 27

) +41 1 940 20 06 2 +41 1 940 22 14

8 http://www.weiss.ch

* weiss@weiss.ch

Image 25
Contents Gambit EQ1-DYN Contents Front Panel Front Panel Groups Introduction Remote ControlProcessing DisplayStatus Display OperationChannel Status Group Peak GroupDither Icon Snapshot DisplayBand Parameters What Is a Band?Range Controls Dynamic Correcting musical instrument volume imbalancesMode SetupOn/Off Comparison BackupRecall StoreDumping Backup will overwrite safe snapshots ResetLoading Dither Display ResolutionLCD Contrast EQ BypassSelf Test Software InformationProtocol ChannelAES/EBU Input Technical DataAES/EBU Output AES/EBU Channel Status DataOutput selected Consumer format Output selected Professional format Overload PowerFilters Frequencies in Hertz Parameter TableBoost/Cuts, applicable to shelving and peaking filters Applicable to peaking filtersThreshold, applicable to dynamic peaking filters Shape, applicable to shelving filtersSlope, applicable to cut filters Overall GainDither Midi Implementation Remote Control ProtocolCH1 / 2 Select Byte Value Workspace and Settings request RS-422 RS-232