OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER   | TECHNICAL DATA  | 
  | 
  | 
Remote Control Protocol
MIDI Implementation
Parameter Remote Control
All band parameters plus the controls parameters are remote controllable. Each parameter has its corre- sponding MIDI controller number.
According to the different parameters, the controllers are limited in their range. Invalid values are replaced by the maximum allowable values.
Following is a list of the supported MIDI system inclusive commands:
Action  | MIDI Message  | Status Byte | Data Byte(s) | 
  | Comment | 
Restore Snapshot  | Program Change  | 1100 cccc  | 0ppp pppp  | 
  | (cccc) Channel No.  | 
  | 
  | 
  | 
  | 
  | 0 - 127  | 
  | 
  | 
  | 
  | 
  | (ppppppp) New Prog No:  | 
Adjust Boost/Cut  | Control Change  | 1011 cccc  | 00000000 ($00)  | 
  | (cccc) Channel No.  | 
CH1 Band 1  | 
  | 
  | 0vvv vvvv  | 
  | (vvvvvvv) New Value:  | 
  | 
  | 
  | 
  | 
  | 0 - 127  | 
Adjust Q  | Control Change  | 1011 cccc  | 00000001 ($01)  | 
  | (cccc) Channel No.  | 
CH1 Band 1  | 
  | 
  | 0vvv vvvv  | 
  | (vvvvvvv) New Value:  | 
  | 
  | 
  | 
  | 
  | 0 - 127  | 
Adjust Frequency  | Control Change  | 1011 cccc  | 00000010 ($02)  | 
  | (cccc) Channel No.  | 
CH1 Band 1  | 
  | 
  | 0vvv vvvv  | 
  | (vvvvvvv) New Value:  | 
  | 
  | 
  | 
  | 
  | 0 - 127  | 
Adjust Slope  | Control Change  | 1011 cccc  | 00000011 ($03)  | 
  | (cccc) Channel No.  | 
CH1 Band 1  | 
  | 
  | 0vvv vvvv  | 
  | (vvvvvvv) New Value:  | 
  | 
  | 
  | 
  | 
  | 0 - 2  | 
Adjust Band Mode  | Control Change  | 1011 cccc  | 00000100 ($04)  | 
  | (cccc) Channel No.  | 
CH1 Band 1  | 
  | 
  | 0vvv vvvv  | 
  | (vvvvvvv) New Value:  | 
  | 
  | 
  | 
  | 
  | 0 - 9  | 
CH1 Band 2  | Control Change  | ...  | $05 - $09  | 
  | 
  | 
CH1 Band 3  | Control Change  | ...  | $0A - $0E  | 
  | 
  | 
CH1 Band 4  | Control Change  | ...  | $0F - $13  | 
  | 
  | 
CH1 Band 5  | Control Change  | ...  | $14 - $18  | 
  | 
  | 
CH1 Band 6  | Control Change  | ...  | $19 - $1D  | 
  | 
  | 
CH1 Band 7  | Control Change  | ...  | $1E - $22  | 
  | 
  | 
CH2 Band 1  | Control Change  | ...  | $23 - $27  | 
  | 
  | 
CH2 Band 2  | Control Change  | ...  | $28 - $2C  | 
  | 
  | 
CH2 Band 3  | Control Change  | ...  | $2D - $31  | 
  | 
  | 
CH2 Band 4  | Control Change  | ...  | $32 - $36  | 
  | 
  | 
CH2 Band 5  | Control Change  | ...  | $37 - $3B  | 
  | 
  | 
CH2 Band 6  | Control Change  | ...  | $3C - $40  | 
  | 
  | 
CH2 Band 7  | Control Change  | ...  | $41 - $45  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Overall Gain CH1  | Control Change  | 1011 cccc  | $46  | 
  | (cccc) Channel No.  | 
  | 
  | 
  | 0vvv vvvv  | 
  | (vvvvvvv) New Value:  | 
  | 
  | 
  | 
  | 
  | 0 - 127  | 
Daniel Weiss Engineering Ltd., Florastr. 42,   | 
  | Page 23 of 27  | 
) +41 1 940 20 06 2 +41 1 940 22 14  | 8 http://www.weiss.ch  | * weiss@weiss.ch  |