Edelweiss EQ1-DYN manual Remote Control Protocol, Midi Implementation

Page 23

OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-DYN

TECHNICAL DATA

 

 

Remote Control Protocol

MIDI Implementation

Parameter Remote Control

All band parameters plus the controls parameters are remote controllable. Each parameter has its corre- sponding MIDI controller number.

According to the different parameters, the controllers are limited in their range. Invalid values are replaced by the maximum allowable values.

Following is a list of the supported MIDI system inclusive commands:

Action

MIDI Message

Status Byte

Data Byte(s)

 

Comment

Restore Snapshot

Program Change

1100 cccc

0ppp pppp

 

(cccc) Channel No.

 

 

 

 

 

0 - 127

 

 

 

 

 

(ppppppp) New Prog No:

Adjust Boost/Cut

Control Change

1011 cccc

00000000 ($00)

 

(cccc) Channel No.

CH1 Band 1

 

 

0vvv vvvv

 

(vvvvvvv) New Value:

 

 

 

 

 

0 - 127

Adjust Q

Control Change

1011 cccc

00000001 ($01)

 

(cccc) Channel No.

CH1 Band 1

 

 

0vvv vvvv

 

(vvvvvvv) New Value:

 

 

 

 

 

0 - 127

Adjust Frequency

Control Change

1011 cccc

00000010 ($02)

 

(cccc) Channel No.

CH1 Band 1

 

 

0vvv vvvv

 

(vvvvvvv) New Value:

 

 

 

 

 

0 - 127

Adjust Slope

Control Change

1011 cccc

00000011 ($03)

 

(cccc) Channel No.

CH1 Band 1

 

 

0vvv vvvv

 

(vvvvvvv) New Value:

 

 

 

 

 

0 - 2

Adjust Band Mode

Control Change

1011 cccc

00000100 ($04)

 

(cccc) Channel No.

CH1 Band 1

 

 

0vvv vvvv

 

(vvvvvvv) New Value:

 

 

 

 

 

0 - 9

CH1 Band 2

Control Change

...

$05 - $09

 

 

CH1 Band 3

Control Change

...

$0A - $0E

 

 

CH1 Band 4

Control Change

...

$0F - $13

 

 

CH1 Band 5

Control Change

...

$14 - $18

 

 

CH1 Band 6

Control Change

...

$19 - $1D

 

 

CH1 Band 7

Control Change

...

$1E - $22

 

 

CH2 Band 1

Control Change

...

$23 - $27

 

 

CH2 Band 2

Control Change

...

$28 - $2C

 

 

CH2 Band 3

Control Change

...

$2D - $31

 

 

CH2 Band 4

Control Change

...

$32 - $36

 

 

CH2 Band 5

Control Change

...

$37 - $3B

 

 

CH2 Band 6

Control Change

...

$3C - $40

 

 

CH2 Band 7

Control Change

...

$41 - $45

 

 

 

 

 

 

 

 

Overall Gain CH1

Control Change

1011 cccc

$46

 

(cccc) Channel No.

 

 

 

0vvv vvvv

 

(vvvvvvv) New Value:

 

 

 

 

 

0 - 127

Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster

 

Page 23 of 27

) +41 1 940 20 06 2 +41 1 940 22 14

8 http://www.weiss.ch

* weiss@weiss.ch

Image 23
Contents Gambit EQ1-DYN Contents Front Panel Front Panel Groups Display Remote ControlIntroduction ProcessingPeak Group OperationStatus Display Channel Status GroupDither Icon Snapshot DisplayRange What Is a Band?Band Parameters Controls Dynamic Correcting musical instrument volume imbalancesOn/Off SetupMode Store BackupComparison RecallLoading Backup will overwrite safe snapshots ResetDumping EQ Bypass Display ResolutionDither LCD ContrastChannel Software InformationSelf Test ProtocolAES/EBU Channel Status Data Technical DataAES/EBU Input AES/EBU OutputOutput selected Consumer format Output selected Professional format Filters PowerOverload Applicable to peaking filters Parameter TableFrequencies in Hertz Boost/Cuts, applicable to shelving and peaking filtersOverall Gain Shape, applicable to shelving filtersThreshold, applicable to dynamic peaking filters Slope, applicable to cut filtersDither Midi Implementation Remote Control ProtocolCH1 / 2 Select Byte Value Workspace and Settings request RS-422 RS-232