SECTION 8 – INSTALLING THE HRU IN A CAPSULE BRACKET
The ACR capsule bracket is a discontinued product that looks like this:
Contents of the HydroFix™ HRU Kit that you will need:
HydroFix™ Replacement
Hydrostatic Release Unit (E)
Capsule design release rod (B)
Keyed bracket adapter (D)
Large cotter pin (H)
HRU expiration label (K)
Instructions: |
| ||
Figure A | |||
1.) | Remove the front cover and carefully release | ||
| |||
| the EPIRB from the bracket. |
| |
2.) | Remove the old HRU unit and rod from the |
| |
| bracket by pressing the spring release back |
| |
| and sliding the old HRU up and out of the |
| |
| bracket. |
| |
3.) | Take the capsule design release rod (B) and |
| |
| place on top of the small rod on the HRU |
| |
| aligning the two sets of holes on the base. (see |
| |
| Figure A). |
| |
4.) | Place large cotter pin (H) through the two |
| |
| holes, securing the two rods together. |
| |
5.) | Place keyed bracket adapter (D) on the bottom of the HRU. This | ||
| part is keyed so that it will fit together only one way. Turn to the right | ||
| until it snaps into place. |
| |
6.) | Mark the expiry date on the HRU according to the instructions in | ||
| Section 3. |
| |