Load default setting

On this page, you can load and store the factory default settings into EEPROM. NOTE: Network settings and MAC address will not be changed.

Press “Load” to load default settings. Reset the device to take effect.

Firmware update

On this page, you can update the firmware via Ethernet.

WARNING! Pressing the ‘Load’ button will immediately erase the flash with no further warning

1.Pressing the “Load” button will erase flash.

2.Wait for erase process to complete.

3.There are two methods to do the Firmware Update action (TFTP or Web):

NOTE: Please avoid loss of network connection, power or other interruption during the firmware upgrade procedure

Web

a.Please type in or browse the target image file in the input field, and then press “update” button to continue.

TFTP

a.Use Windows Command Prompt window to run the tftp client program.

Syntax: tftp -i 10.1.1.1 put FILE_DIRECTORY\FILENAME.bin

b.The firmware update should take about 45 seconds to complete.

c.If the update process somehow goes wrong (like power failure), please connect to http://10.1.1.1 to try and restart the process (you may have to reset the device first)

Instruction Manual

8

Image 12
Contents Port RS232 Serial over IP Ethernet Device Server FCC Compliance Statement Table of Contents Product Applications Product Overview Top ViewFront View Rear ViewLoad Default Settings / System Reset Button LED IndicatorsLoad Default Settings System ResetRJ45 Ethernet Pin Assignments RS-232 DB9 Male Pin AssignmentInstallation Packaging ContentsIntroduction Web Browser MethodBroadcast Search Administrator AuthenticationWeb Console Operation System IP System StatusLoad default setting Firmware updateWeb TCP Mode Telnet Server / ClientCLI Mode Client mode inactive timeoutServer mode protect timeout Reverse TelnetUDP Mode ModeLocal Port Remote AddressBaud rate Character BitsParity Type Stop BitReset Device Hardware Flow ControlUart Memory Overflow count Uart Fifo Overflow countConfiguration Virtual COM Software OperationServer/Client TCP Mode only COM MappingEnable Control Connection TCP Server or Client Only IP AddressRemote Port Seconds for reconnection intervalProduct Applications Specifications ParityTechnical Support Warranty Information Limitation of Liability