NOTE: For more information about using the VMware vSphere CLI, see vmware.com/support.

Configuring Your System To Send Traps To A Management Station

Server Administrator generates SNMP traps in response to changes in the status of sensors and other monitored parameters. One or more trap destinations must be configured on the system running Server Administrator for SNMP traps to be sent to a management station.

To configure your ESXi system running Server Administrator to send traps to a management station:

1.Install the VMware vSphere CLI.

2.Open a command prompt on the system where the VMware vSphere CLI is installed.

3.Change to the directory where the VMware vSphere CLI is installed. The default location on Linux is /usr/bin. The default location on Windows is C:\Program Files\VMware\VMware vSphere CLI\bin.

4.Run the following command: vicfg-snmp.pl --server <server> --username <username> -- password <password> -c <community> -t <hostname> @162/<community>

where <server> is the hostname or IP address of the ESXi system, <username> is a user on the ESXi system, <community> is the SNMP community name and <hostname> is the hostname or IP address of the management station.

NOTE: The extension .pl is not required on Linux.

NOTE: If you do not specify a user name and password, you are prompted.

The SNMP trap configuration takes effect immediately without restarting any services.

Firewall Configuration On Systems Running Supported Red Hat Enterprise Linux Operating Systems And SUSE Linux Enterprise Server

If you enable firewall security while installing Red Hat Enterprise Linux/SUSE Linux, the SNMP port on all external network interfaces is closed by default. To enable SNMP management applications such as IT Assistant to discover and retrieve information from Server Administrator, the SNMP port on at least one external network interface must be open. If Server Administrator detects that the SNMP port is not open in the firewall for any external network interface, Server Administrator displays a warning message and logs a message to the system log.

You can open the SNMP port by disabling the firewall, opening an entire external network interface in the firewall, or opening the SNMP port for at least one external network interface in the firewall. You can perform this action before or after Server Administrator is started.

To open the SNMP port on Red Hat Enterprise Linux using one of the previously described methods:

1.At the Red Hat Enterprise Linux command prompt, type setup and press <Enter> to start the Text Mode Setup Utility.

NOTE: This command is available only if you have performed a default installation of the operating system. The Choose a Tool menu appears.

2.Select Firewall Configuration using the down arrow and press <Enter>. The Firewall Configuration screen appears.

3.Press <Tab> to select Security Level and then press the spacebar to select the security level you want to set. The selected Security Level is indicated by an asterisk.

NOTE: For more information about the firewall security levels, press <F1>. The default SNMP port number is

161.If you are using the X Window System graphical user interface, pressing <F1> may not provide information about firewall security levels on newer versions of Red Hat Enterprise Linux.

a.To disable the firewall, select No firewall or Disabled and go to Step7.

24

Image 24
Contents Dell OpenManage Server Administrator Version 7.3 Users Guide Dell Inc Contents Server Administrator Services Working With Remote Access ControllerServer Administrator Logs Setting Alert ActionsTroubleshooting Frequently Asked QuestionsInstallation Updating Individual System Components IntroductionStorage Management Service Instrumentation ServiceRemote Access Controller What Is New In This ReleaseSystems Management Standards Availability Availability On Supported Operating SystemsServer Administrator Home Other Documents You May NeedOperating System Accessing Documents From Dell Support Site Serviceability Tools Obtaining Technical Assistance Contacting DellOMConnectionsEnterpriseSystemsManagement Setup And Administration Role-Based Access ControlUser Privilege Access Description Level Type View Manage Service User Privilege Level Required ViewAuthentication Microsoft Windows AuthenticationVMware ESX Server 4.X Authentication VMware ESXi Server 5.X AuthenticationEncryption Assigning User PrivilegesAdding Users To a Domain On Windows Operating Systems Creating Users With Power User Privileges Creating Users Creating Users With User PrivilegesUserName HostName Rights Best Practices While Using The Omarolemap File Configuring The Snmp Agent Select Account is disabled and click OKOpen the Computer Management window Snmp Service Properties window appears Changing The Snmp Community NameSnmp Agent Access Control Configuration Snmp Service Configuration window appearsEnabling Snmp Set Operations Server Administrator Snmp Agent Install Actions Sever Administrator Snmp Install Actions Enabling Snmp Access From Remote HostsTo configure the Snmp agent To enable VMWare Snmp service, run the following command Page Firewall Configuration Using Server Administrator Server Administrator Local System LoginLogging In And Out Central Web Server Login Click SubmitUsing The Active Directory Login Single Sign-OnEnabling The Use Of Client-Side Scripts On Internet Explorer Enabling The Use Of Client-Side Scripts On Mozilla FirefoxGUI Field Name Sample Server Administrator Home Page Non-Modular System Features Modular System System/Server Module Component Status Indicators Global Navigation BarSystem Tree Action WindowGauge Indicators Task ButtonsUnderlined Items Using The Online Help Using The Preferences HomeServer Administrator Web Server Preferences Setting User And System PreferencesManaged System Preferences Click General Settings Secure Port SystemCertificate Management Click X.509 CertificateUsing The Server Administrator Command Line Interface Server Administrator Web Server Action TabsServer Administrator Services Managing Your SystemServer Administrator Home Page System Tree Objects Managing System/Server Module Tree ObjectsModular Enclosure Accessing And Using Chassis Management Controller System/Server Module PropertiesModular Enclosure object Tab Properties Subtab Information Licensing Subtabs Information LicensingSubtabs Hardware Alert Command ShutdownLogs Alert ManagementMain System Chassis/Main System Session ManagementSubtabs Session Main System Chassis/Main System Properties Properties and Setup Subtab Information Setup Subtab BiosBatteries Properties Subtab InformationFans FirmwareHardware Performance Intrusion MemoryProperties Subtab Intrusion Properties Subtab MemoryPower Management NetworkPorts Subtab Information PropertiesPower Supplies Management Subtabs Budget ProfilesAlert Management Properties Subtab Elements Remote Access ProcessorsAlert Management Subtabs Alert Actions Temperatures Subtab Temperature Probes PropertiesRemovable Flash Media SlotsVoltages SoftwareOperating System Properties Subtab Voltage ProbesManaging Preferences Home Page Configuration Options General SettingsStorage Server Administrator Subtabs Access Configuration Snmp Configuration PreferencesWorking With Remote Access Controller Modular Enclosure Modular system Server Modules Main SystemRemote Access Device Viewing Basic InformationSystem Main System ChassisIPv4 Address IPv6 AddressVlan ID Click Apply ChangesClick Serial Port Serial Port Configuration window appears Click Apply Changes Click Terminal Mode SettingsAdditional Configuration For iDRAC Configuring Remote Access Device UsersClick Additional Configuration Setting Platform Event Filter Alerts None Reboot SystemPower Off System Power Cycle SystemSetting Platform Event Alert Destinations Server Administrator Logs Integrated FeaturesServer Administrator Logs Log Window Task ButtonsHardware Log Alert LogMaintaining The Hardware Log StatusCommand Log Setting Alert Actions Example 1 ps -ef /tmp/psout.txt 2&1Setting Alert Action Execute Application In Windows Server BMC/iDRAC Platform Events Filter Alert MessagesEvent Description Troubleshooting Connection Service FailureLogin Failure Scenarios Opt/dell/srvadmin/sbin/dsmomconnsvcdOpenManage Server Administrator Services Service Name Description Impact of FailureSeverity Dsmsadatamgr Frequently Asked Questions Are there other ports users can use apart from 1311?Port ITA communicating with Linux systems