Furuno 851 MARK-2 installation manual How to fix signal cable in cable gland

Page 14

1.MOUNTING

5.Position the signal cable so that no more than 4 cm of the sheath is exposed as shown in the figure below. Tighten fixing bolts.

 

Tubing

 

Shield

 

Sheath

Within 4 cm

Bolt

 

Plate

Gasket

Flat

washer

CABLE GLAND

Figure 1-12 How to fix signal cable in cable gland

6. Unfasten four screws shown in the figure below.

Four screws

Figure 1-13 Antenna unit chassis, cover opened

7. Pass the signal cable through the cable protector.

Cable protector

Figure 1-14 Antenna unit chassis, cover opened

8.Connect the signal cable to the RTB Board (03P9249), referring to the interconnection diagram and the figure below.

1-8

Image 14
Contents Installation Manual Marine Radar Model 851 MARK-2 First Edition Safety Instructions Only qualified personnel System Configuration Equipment Lists Mounting Mounting Methods for Antenna UnitFixing Holes in Mounting Platform Fastening the Radiator to the Radiator BracketMounting the Antenna Unit Outside fixing holesAntenna unit How to fasten antenna unit to mounting platform Fixing holes inside antenna unit Connecting the Signal Cable 10 Antenna unit chassis, cover opened12 How to fix signal cable in cable gland 15 Antenna unit chassis, cover opened Mounting Methods for Display Unit Mounting the Display Unit Servicing ClearanceWiring ConnectionsSignal cable connection Input/Output Data List InputAttaching Option Connector Display unit rear viewConnection of two Nmea equipments Installation Check List TDH TDC ShieldAdjustment Checking magnetron heater voltageInitial Adjustment of Picture STC AutomanDisplaying the Installation Menus Main MenuEntering Initial Settings Installation setup 2 menuHeading Alignment Sweep Timing Inward OutwardPage Page Page Page Page Page