Furuno 1832, 1942, 1932 manual Equipment List

Page 11

EQUIPMENT LIST

Complete Set

MODEL 1832

 

Name

Type

Code No.

Qty

Remarks

1

Antenna Unit

RSB-0071-057

 

1

 

 

 

 

 

 

 

2

Display Unit

RDP-118

 

1

 

 

 

 

 

 

 

 

Installation Materials

CP03-16900

000-086-843

 

sig. cable assy. 10 m

 

(select one)

 

 

 

 

3

CP03-16910

000-086-844

1 set

sig. cable assy. 15 m

 

 

 

 

 

 

CP03-16920

000-086-845

sig. cable assy. 20 m

 

 

 

 

 

 

 

 

 

 

 

CP03-16930

000-086-846

 

sig. cable assy. 30 m

 

 

 

 

 

 

4

Accessaries

FP03-06400

000-086-872

1 set

 

 

 

 

 

 

 

5

Spare Parts

SP03-12200

000-086-965

1 set

 

 

 

 

 

 

 

MODEL 1932/1942

 

Name

Type

Code No.

Qty

Remarks

1

Antenna Unit

RSB-0061-054A

 

1

For MODEL1932

RSB-0062-055A

 

1

For MODEL1942

 

 

 

2

Display Unit

RDP-118

 

1

 

 

 

 

 

 

 

 

Installation Materials

CP03-17000

000-086-848

 

sig. cable assy. 10 m

 

(select one)

 

 

 

 

3

CP03-17010

000-086-849

1 set

sig. cable assy. 15 m

 

 

CP03-17020

000-086-850

sig. cable assy. 20 m

 

 

 

 

 

 

 

 

 

 

 

CP03-17030

000-086-851

 

sig. cable assy. 30 m

 

 

 

 

 

 

4

Accessaries

FP03-06400

000-086-872

1 set

 

 

 

 

 

 

 

5

Spare Parts

SP03-12200

000-086-965

1 set

 

Optional Equipment

 

Name

Type

Code No.

Qty

Remarks

1

ARP Board

ARP-10

000-086-852

1

 

 

 

 

 

 

 

 

Rectifier

PR-62

000-013-484

 

1832, 100V AC

 

 

 

 

 

 

 

 

 

000-013-485

1

1832, 110V AC

 

 

 

 

 

2

 

 

000-013-486

1832, 220V AC

 

 

 

 

 

 

 

 

 

 

 

 

000-013-487

 

1832, 230V AC

 

 

 

 

 

 

 

 

RU-3423

000-030-443

1

1932/1942, AC

 

 

 

 

 

 

3

Magnifying Lens

03-121-1500

008-439-000

1

 

 

 

 

 

 

 

4

Flush Mount Kit

OP03-145

008-476-060

1

 

 

 

 

 

 

 

5

Mounting Bracket (1)

OP03-92

008-445-070

1

For MODEL1832

 

 

 

 

 

 

6

External Buzzer

OP03-21

000-030-097

1

*See note 1.

 

 

 

 

 

 

 

Cable Assy.

MJ-A6SPF0003-050

000-117-603

 

 

 

 

 

 

 

 

 

 

MJ-A6SPF0009-100

000-125-236

 

 

 

 

 

 

 

 

7

 

MJ-A6SPF0007-100

000-125-237

1

 

 

 

 

 

 

MJ-A6SPF00012-100

000-133-817

 

 

 

 

 

 

 

 

 

 

 

 

 

MJ-A6SPF00012-050

000-134-424

 

 

 

 

 

 

 

 

 

 

MJ-B24LPF0006-005

000-140-438

 

*See note 2.

 

 

 

 

 

 

Note 1) Even though the display unit meets waterproof standard IPX-5, the connection of external buzzer, radar plotter and/or remote display can affect waterproofness. Watertight integrity cannot be guaranteed. When these modification has been done, the display unit should not be mounted where exposed.

Note 2) Conversion from MCP connector (square type) to MJ connector (circular type).

ix

Image 11
Contents Page 00080788713 Important Notices Radio Frequency Radiation Hazard Compliance with R&TTE Directive 1999/5/EC Foreword Table of Contents Model 1832 Specifications Vii SpecificationsViii OptionEquipment List Installation Materials Configuration of Model 1832/1932/1942 Xii Radar Display What is Radar?How Radar Determines Range How Radar Determines BearingHow radar works Control Description Basic Operation125 NM Display Indication and MarkersStand-by Economy modeTurning the Radar On/Off TransmittingSelecting the Range Adjusting Picture BrillianceAdjusting Receiver Sensitivity Adjusting the A/C SEA Control reducing sea clutterAdjusting A/C Rain Adjusting the A/C Rain Control reducing rain clutterAdjusting the A/C SEA control Tip for adjusting the A/C SEABy cursor Erasing the Heading Line, North MarkMeasuring the Range By range ringPredicting collision course Using the Offset EBLMeasuring the Bearing By EBLMeasuring range and bearing between two targets Cancelling shifted pictureShifting off centering the Picture Zoom Cancelling zoomPress the Menu key to close the menu Selecting the Presentation ModeBasic Menu Operation Magnifying Long Range Echoes echo stretch Echo TrailSelect OFF deactivate at Echo Trail on the menu Suppressing Radar InterferenceMentally create the guard zone you want to set Guard AlarmSelecting Pulsewidth Guard WatchmanGo into the Others menu, and set 15. Watchman for off Displaying Navigation DataFollowing summarizes the Other Menu Other Menu DescriptionOutputting Target Position Adjusting Brilliance of MarkersFunction Keys Suppressing NoiseIndirect Echoes Multiple EchoesSide-lobe Echoes Indirect echoes Blind and Shadow SectorsMaintenance & Troubleshooting Troubleshooting Self Test Mounting Model Where the temperature is more than 70 CUnpacking the antenna unit Siting, handling considerationsMounting platform Wiring and final preparationMounting Model 1932 Connections Fasten the cable gland assemblyWaveguide Groove Final preparationMounting Navigation aid, video sounder con- nectionYou will need an Nmea cable Mounting considerationsInput/Output Data List Heading signal can be connected to the HDG connectorHeading Sensor Connection Preparation Tick boxEntering antenna height Adjusting tune/videoWhen adjustment is completed, the mes- sages disappears Adjusting sweep timing Adjustment range0.000~3.239nm Adjusting MBS Adjustment 0.00~0.25Magnetron heater voltage Setting a blanking areaThis page is intentionally left blank Menu Tree ARP-10 Option Targets Limits, Visual alarm against lostTargets violating CPA/TCPA AP-4 Auto acquisition area is predefined between One minute after acquisition Vector still un- reliableAP-6 AP-7 Make sure the follows on Self Test menu ARP-10Not used Page Hatai Page Marine Radar Marine Radar