3.The continuous load demand from the equipment or device being operated exceeds the continuous load rating of the inverter being used. Solution: use a higher capacity inverter or lower rated device.
4.The case temperature becomes hot (exceeds 145°F). Solution: allow the inverter to cool. Do not block the cooling slots or air flow over and through the inverter. Reduce the load on the inverter to the continuous rated output.
RESET: To reset after shutdown occurs, remove the
7.IF THE INVERTER FUSE BLOWS
Your power inverter is fitted with a fuse, which should not have to be replaced under normal operating conditions. A blown fuse is usually caused by reverse polarity or a short circuit within the device or equipment being operated.
If the fuse does blow:
1.Disconnect the device or equipment immediately.
2.Find the source of the problem, and repair it.
3.Install a new
4.Do not
ATTENTION: Do not install a fuse higher than