Connect the Equipment

Battery backup and surge outlets

Connect equipment to the outlets on the rear panel of the unit.

Battery backup outlets—connect equipment that requires power during a power outage to these outlets, such as a computer or DVR.

Surge Protection only outlets—connect noncritical equipment to these outlets, as these outlets will not have power during a power outage. The outlets continue to provide surge protection, even if the unit if OFF.

Note: The number of components plugged into the battery backup outlets will determine the battery run time. The more components that draw power from the battery backup outlets during a power outage, the less battery backup time the unit will be able to provide.

Power-saving Master and Controlled outlets (J35 units only)

When the power-saving feature is enabled, the J35B reduces power consumption by automatically disconnecting utility power to devices that are not in use.

When the device connected to the Master outlet goes into sleep or standby mode, the J35B will disconnect power to components connected to the Controlled by Master outlets, conserving energy.

For example, if a desktop computer is connected to the Master outlet, when it goes into sleep mode, the J35B will disconnect power peripheral devices connected to the Controlled by Master outlets, such as a monitor, printer, and speakers.

1.Before connecting components to the unit, determine which components will utilize the Master and Controlled outlets.

Connect a master device such as a TV to the Master outlet.

Connect peripheral devices such as amplifiers, DVD players, or sub-woofers to the Controlled outlets.

2.Connect components to the outlets on the back panel of the unit.

4

APC A/V J Type Power Conditioner and Battery Backup

Image 8
Contents Installation and Operation Page General Information Page Overview Inventory Safety General Information Rear view ComponentsFront view Connect Input Power InstallationConnect the Battery Connect the Equipment Battery backup and surge outletsPower-saving Master and Controlled outlets J35 units only Operation Display Interface MenusStart up menu screens Status menuSetup menu Audio Alarm OFF Press to Chng Screen saver. Turn the screen saver on or off Troubleshooting Problem Possible Cause Corrective ActionContact APC APV Technical Support Warranty SpecificationsReplacement Battery Page Page Inventario Seguridad Información generalDescripción general Vista posterior ComponentesVista delantera Conexión de la alimentación de entrada InstalaciónConexión de la batería Conexión de los equipos Funcionamiento Menús de la interfaz de pantallaPantallas de menús de inicio Menú Status estadoMenú de configuración Audio Alarm OFF Press to Chng Salvapantallas. Puede activar o desactivar el salvapantallas Resolución de problemas Problema Posible causa Acción correctivaEspecificaciones Batería de recambioPage Page Inventaire Sécurité Informations généralesPrésentation Vue arrière ComposantsVue de face Connexion de la batterie Connexion de l’alimentation d’entréeConnexion de l’équipement Fonctionnement Menus de l’interface d’affichageEcrans du menu de démarrage Menu Status EtatMenu Setup Configuration Audio Alarm OFF Press to Chng Ecran de veille. Activez ou désactivez l’écran de veille Dépannage Problème Cause probable Mesure correctiveAssistance technique d’APC APV Garantie CaractéristiquesBatterie de rechange Page Page APC Worldwide Customer Support 990-3712A 04/2010