Xantrex Technology 806-1020, 806-1055 Precautions for Using Rechargeable Appliances, Regulatory

Page 10

Precautions for Using Rechargeable Appliances

RISK OF DAMAGE TO RECHARGEABLE APPLIANCES

Most rechargeable battery-operated equipment uses a separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output.

Some chargers for small rechargeable batteries can be damaged if connected to the Freedom HF. Avoid using the following with the Freedom HF:

Small battery-operated appliances like flashlights, razors, and night lights that can be plugged directly into an AC receptacle to recharge.

Some chargers for battery packs used in power hand tools. These affected chargers display a warning label stating that dangerous voltages are present at the battery terminals.

If you are unsure about using your rechargeable appliance with the Freedom HF, contact the equipment manufacturer to find out if the appliance is acceptable for use with an inverter that has a modified sine wave output voltage.

Failure to follow these instructions can damage the unit and/or damage other equipment.

Regulatory

The Freedom HF Inverter/Charger is certified to appropriate US and Canadian standards. For more information see “Regulatory Approvals” on page 37.

The Freedom HF Inverter/Charger is intended to be used for mobile or commercial applications. This inverter/charger is designed for marine applications only when additional drip protection is installed in certain orientations. See the installation guide for information.

It is not intended for other applications as it may not comply with the additional safety code requirements needed for those other applications. See “Limitations On Use” below.

LIMITATIONS ON USE

Do not use in connection with life support systems.

Failure to follow these instructions can result in death or serious injury.

NOTE: The Freedom HF Inverter/Charger is a modified sine wave inverter/ charger. Please ensure your equipment or devices are compatible with modified sine wave prior to usage.

viii

Freedom HF Installation Guide

Image 10
Contents Freedom HF Inverter/Chargers Page Document Part Number About This Guide Statement of HazardRelated Information Important Safety Instructions Electrical Shock HazardFire and Burn Hazard Explosion HazardPrecautions When Working With Batteries Fire Hazard Precautions When Preparing to ChargeExposure to Chemicals and Gases Hazard Risk of Damage to the INVERTER/CHARGERRisk of Damage to Rechargeable Appliances Precautions for Using Rechargeable AppliancesRegulatory Limitations on USEFCC Information to the User KKK Information to the UserPage Contents Page Materials List What’s In The Box Display panel is attached to the unitInstallation Codes Safety InstructionsShock Hazard Installation Tools and Materials High Level Overview of Installation Steps Basic Installation Procedures Designing the Installation To engineGenerator AC shore powerAC Disconnect and Over-Current Protection Device AC Cabling AC Distribution PanelsEquipment Damage AC Grounding AC Output Neutral BondingDC Cabling DC Disconnects and Over-Current Devices Ground Fault Circuit Interrupters GFCIsBatteries Fire and Explosion Hazards Close to the battery compartment and the AC source and loadChoosing a Location for the Unit Splashing water or bilge waterMounting the Unit To mount the Freedom HFConnecting the Equipment Ground Grounding LocationsGeneral AC Wiring Considerations Connecting the AC Input WiresFIRE, SHOCK, and Energy Hazards Installers only Damage other equipmentAC Input Connections for the Freedom HF 1800 T Model Electric Shock Hazard Connecting AC Output to an Existing AC Circuit To make a permanent connection to existing AC wiring AC Output Connections for the Freedom HF 1800 T ModelGND Reverse Polarity DamageConnecting the DC Cables DC End for Freedom HF 1000, 1055, 1800, and 1800 TTo make the DC connections For use by qualified installers DC Grounding Anderson ConnectorsTo connect the DC ground To enable ignition control Exposed Ignition Control TerminalsPower Module For Freedom HF 1055 EMS and 1800 EMS To enable ignition control and to connect auxiliary DC powerUse by qualified installers only Mounting the Display Panel To mount the display panelTesting in Invert Mode Testing Your InstallationTo test the Freedom HF in invert mode Testing in Shore Power Mode To test the Freedom HF in shore power modeDrip Shield Installation For Marine Installations Different ViewsDrip Shield Installation For Marine Installations To install the drip shieldsConfiguration Marine Installation Typical Marine InstallationSpecifications Physical SpecificationsDC Input AC Input Page Page Xantrex Technology USA Inc
Related manuals
Manual 64 pages 12.33 Kb

806-1055-02 806-1840, 806-1055, 806-1020, 806-1840-01, 806-1840-02 specifications

Xantrex Technology is renowned for its innovative power solutions, and among its extensive product lineup, the model numbers 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 stand out for their sophisticated features and reliable performance. These models are primarily designed to meet the diverse energy needs in off-grid, mobile, and backup power applications.

The Xantrex 806 family is characterized by its versatility and high efficiency. One of the standout features across these models is their pure sine wave inverter technology. This technology ensures that the power output closely mimics utility-provided electricity, making it safe to use with sensitive electronics such as computers and medical equipment. The clean, reliable power allows users to operate a variety of appliances without the risk of damaging electrical devices.

Another key characteristic is the ability of these inverters to provide a robust surge capability. This is crucial for starting up heavy equipment or appliances that require a higher initial power draw, such as refrigerators and air conditioners. Users can feel confident knowing that these inverters can handle demanding loads without compromising performance.

Scalability is also a notable feature of the Xantrex 806 models. Users can easily integrate multiple units to expand their power capacity, making them suitable for anything from small RVs to larger off-grid installations. The inverters include advanced communication features, allowing for easy monitoring and management of energy consumption via remote control systems.

Furthermore, these models incorporate user-friendly designs with features aimed at enhancing usability. For instance, the LED indicators provide real-time information about the operational status and battery levels, enabling users to quickly assess their power system’s performance.

Durability and reliability are critical considerations for any power solution, and the Xantrex 806 series meets these demands effectively. Built with high-quality materials, these inverters are designed to withstand the rigors of daily use in various environments, from remote camping sites to urban settings. With built-in safety features such as overload protection, short circuit protection, and thermal shutdown, they provide peace of mind for users.

In summary, the Xantrex Technology models 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 exemplify advanced engineering in power inverter technology. With their pure sine wave output, impressive surge capability, scalability, and durable construction, they offer reliable solutions for users seeking effective energy management in diverse applications.