Basic Installation Procedures

Step 3: Mounting the Unit

To mount the Freedom HF:

1.Remove the Freedom HF from its shipping container, verify that all components are present, and record relevant product information on “Information About Your System” in the Owner’s Guide.

2.Select an appropriate mounting location and orientation. (See Figure 2 below.) To meet regulatory requirements, for use in on-land applications, the Freedom HF must be mounted in one of the following orientations:

Under a horizontal surface (see 1)

In a horizontal position on a vertical surface (see 2)

NOTE: For marine installations, only this orientation is allowed, due to the probability of moisture finding access into the enclosure.

1

2

3

See page 31 for drip shield installation on Marine applications.

On a horizontal surface (see 3)

Figure 2 Approved Mounting Orientations

3.Look for the mounting template and unfold. Tape it to the mounting surface and pilot-drill the desired number of mounting holes. Remove the template.

4.Fasten the Freedom HF to the mounting surface. If you are mounting the unit on a wall or bulkhead, use #12 or #14 pan-head wood or sheet metal screws to secure it to the framing behind the wall or bulkhead.

Alternatively, use nut inserts and 1/4-20 machine screws.

12

Freedom HF Installation Guide

Image 26 Contents
Freedom HF Inverter/Chargers Page Document Part Number About This Guide Statement of HazardRelated Information Important Safety Instructions Electrical Shock HazardFire and Burn Hazard Explosion HazardPrecautions When Working With Batteries Fire Hazard Precautions When Preparing to ChargeExposure to Chemicals and Gases Hazard Risk of Damage to the INVERTER/CHARGERRisk of Damage to Rechargeable Appliances Precautions for Using Rechargeable AppliancesRegulatory Limitations on USEFCC Information to the User KKK Information to the UserPage Contents Page Materials List What’s In The Box Display panel is attached to the unitShock Hazard Safety InstructionsInstallation Codes Installation Tools and Materials High Level Overview of Installation Steps Basic Installation Procedures Designing the Installation To engineAC Disconnect and Over-Current Protection Device AC shore powerGenerator Equipment Damage AC Distribution PanelsAC Cabling DC Cabling AC Output Neutral BondingAC Grounding Batteries Ground Fault Circuit Interrupters GFCIsDC Disconnects and Over-Current Devices Fire and Explosion Hazards Close to the battery compartment and the AC source and loadChoosing a Location for the Unit Splashing water or bilge waterMounting the Unit To mount the Freedom HFConnecting the Equipment Ground Grounding LocationsFIRE, SHOCK, and Energy Hazards Connecting the AC Input WiresGeneral AC Wiring Considerations Installers only Damage other equipmentAC Input Connections for the Freedom HF 1800 T Model Electric Shock Hazard Connecting AC Output to an Existing AC Circuit To make a permanent connection to existing AC wiring AC Output Connections for the Freedom HF 1800 T ModelGND Reverse Polarity DamageConnecting the DC Cables DC End for Freedom HF 1000, 1055, 1800, and 1800 TTo make the DC connections For use by qualified installers To connect the DC ground Anderson ConnectorsDC Grounding To enable ignition control Exposed Ignition Control TerminalsPower Module For Freedom HF 1055 EMS and 1800 EMS To enable ignition control and to connect auxiliary DC powerUse by qualified installers only Mounting the Display Panel To mount the display panelTo test the Freedom HF in invert mode Testing Your InstallationTesting in Invert Mode Testing in Shore Power Mode To test the Freedom HF in shore power modeDrip Shield Installation For Marine Installations Different ViewsDrip Shield Installation For Marine Installations To install the drip shieldsConfiguration Marine Installation Typical Marine InstallationSpecifications Physical SpecificationsDC Input AC Input Page Page Xantrex Technology USA Inc