Xantrex Technology 806-1055-02 806-1840, 806-1020, 806-1840-01 manual Basic Installation Procedures

Page 19

Basic Installation Procedures

Xantrex recommends that you have your installation performed by a qualified technician or electrician.

This section provides sample installation information as a guide for your installation. For your convenience, the overall procedure is divided into ten main steps:

Step 1: Designing an installation. (Start on page 6.)

Step 2: Choosing a location for the Freedom HF. (Start on page 11.)

Step 3: Mounting the Freedom HF. (Start on page 12.)

Step 4: Connecting the AC input wires. (Start on page 14.)

Step 5: Connecting the AC output wires. (Start on page 18.)

Step 6: Connecting the DC cables. (Start on page 21.)

Step 7: Mounting the display panel. (Start on page 28.)

Step 8: Testing your installation. (Start on page 29.)

This guide for use by qualified installers only.

975-0395-01-01

5

Image 19
Contents Freedom HF Inverter/Chargers Page Document Part Number Statement of Hazard About This GuideRelated Information Electrical Shock Hazard Important Safety InstructionsExplosion Hazard Fire and Burn HazardPrecautions When Working With Batteries Risk of Damage to the INVERTER/CHARGER Precautions When Preparing to ChargeExposure to Chemicals and Gases Hazard Fire HazardLimitations on USE Precautions for Using Rechargeable AppliancesRegulatory Risk of Damage to Rechargeable AppliancesKKK Information to the User FCC Information to the UserPage Contents Page What’s In The Box Display panel is attached to the unit Materials ListInstallation Codes Safety InstructionsShock Hazard Installation Tools and Materials High Level Overview of Installation Steps Basic Installation Procedures To engine Designing the InstallationGenerator AC shore powerAC Disconnect and Over-Current Protection Device AC Cabling AC Distribution PanelsEquipment Damage AC Grounding AC Output Neutral BondingDC Cabling DC Disconnects and Over-Current Devices Ground Fault Circuit Interrupters GFCIsBatteries Splashing water or bilge water Close to the battery compartment and the AC source and loadChoosing a Location for the Unit Fire and Explosion HazardsTo mount the Freedom HF Mounting the UnitGrounding Locations Connecting the Equipment GroundGeneral AC Wiring Considerations Connecting the AC Input WiresFIRE, SHOCK, and Energy Hazards Damage other equipment Installers onlyAC Input Connections for the Freedom HF 1800 T Model Electric Shock Hazard Connecting AC Output to an Existing AC Circuit AC Output Connections for the Freedom HF 1800 T Model To make a permanent connection to existing AC wiringReverse Polarity Damage GNDDC End for Freedom HF 1000, 1055, 1800, and 1800 T Connecting the DC CablesTo make the DC connections For use by qualified installers DC Grounding Anderson ConnectorsTo connect the DC ground Exposed Ignition Control Terminals To enable ignition controlTo enable ignition control and to connect auxiliary DC power Power Module For Freedom HF 1055 EMS and 1800 EMSUse by qualified installers only To mount the display panel Mounting the Display PanelTesting in Invert Mode Testing Your InstallationTo test the Freedom HF in invert mode To test the Freedom HF in shore power mode Testing in Shore Power ModeDifferent Views Drip Shield Installation For Marine InstallationsTo install the drip shields Drip Shield Installation For Marine InstallationsConfiguration Typical Marine Installation Marine InstallationPhysical Specifications SpecificationsDC Input AC Input Page Page Xantrex Technology USA Inc
Related manuals
Manual 64 pages 12.33 Kb

806-1055-02 806-1840, 806-1055, 806-1020, 806-1840-01, 806-1840-02 specifications

Xantrex Technology is renowned for its innovative power solutions, and among its extensive product lineup, the model numbers 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 stand out for their sophisticated features and reliable performance. These models are primarily designed to meet the diverse energy needs in off-grid, mobile, and backup power applications.

The Xantrex 806 family is characterized by its versatility and high efficiency. One of the standout features across these models is their pure sine wave inverter technology. This technology ensures that the power output closely mimics utility-provided electricity, making it safe to use with sensitive electronics such as computers and medical equipment. The clean, reliable power allows users to operate a variety of appliances without the risk of damaging electrical devices.

Another key characteristic is the ability of these inverters to provide a robust surge capability. This is crucial for starting up heavy equipment or appliances that require a higher initial power draw, such as refrigerators and air conditioners. Users can feel confident knowing that these inverters can handle demanding loads without compromising performance.

Scalability is also a notable feature of the Xantrex 806 models. Users can easily integrate multiple units to expand their power capacity, making them suitable for anything from small RVs to larger off-grid installations. The inverters include advanced communication features, allowing for easy monitoring and management of energy consumption via remote control systems.

Furthermore, these models incorporate user-friendly designs with features aimed at enhancing usability. For instance, the LED indicators provide real-time information about the operational status and battery levels, enabling users to quickly assess their power system’s performance.

Durability and reliability are critical considerations for any power solution, and the Xantrex 806 series meets these demands effectively. Built with high-quality materials, these inverters are designed to withstand the rigors of daily use in various environments, from remote camping sites to urban settings. With built-in safety features such as overload protection, short circuit protection, and thermal shutdown, they provide peace of mind for users.

In summary, the Xantrex Technology models 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 exemplify advanced engineering in power inverter technology. With their pure sine wave output, impressive surge capability, scalability, and durable construction, they offer reliable solutions for users seeking effective energy management in diverse applications.