Basic Installation Procedures
AC Input Connections for the Freedom HF 1000, Freedom HF 1055, and Freedom HF 1800 Models
AC Input Connections for the Freedom HF 1800 T Model
10mm | clamp slot | |
|
|
|
to circuit breaker
terminal opening
AC |
|
|
IN |
|
|
L | G | N |
TEST
TEST
to circuit breaker
TEST | TEST |
| RESET | RESET |
1.Ensure AC and DC power sources are turned off.
2.Install the required circuit breaker in the AC distribution panel supplying AC power to the unit.
3.Strip a single strand (e.g. Romex®)1 AC input wire, as appropriate.
4.Locate the Line, Ground and Neutral terminals on the AC input terminal labeled as L, G, and N respectively.
5.Using a 3.5mm slot long neck screwdriver, open the WAGO cage clamp by inserting the tool in the clamp slot for Ground terminal.
6.Insert Ground AC wire into Ground terminal slot on the unit.
7.Repeat steps 5 and 6 for Line and Neutral connections.
8.Connect the other end of the wires to the circuit breaker in the AC distribution panel supplying AC power to the unit.
1.Romex is brand name owned by Southwire, used here as an example but not as an endorsement of a particular brand.
1.Ensure AC and DC power sources are turned off.
2.Install the required circuit breaker in the AC distribution panel supplying AC power to the unit.
3.Connect the female PTI cable connector to the AC IN male receptacle on the unit.
4.Connect the other end of the wires to the circuit breaker in the AC distribution panel supplying AC power to the unit.
16 | Freedom HF Installation Guide |