Dell 8 manual Dcbx port-role auto-downstream

Page 14

Resource

Prerequisites

 

 

MXL

• DCB needs to be enabled.

 

• VLT needs to be disabled.

 

• FIP Snooping feature needs to be enabled on

 

the MXL.

 

conf

 

Feature fip-snooping

 

Port-channel member interfaces needs to have

 

below configuration.

 

interface range tengigabitethernet

 

0/33 – 36

 

port-channel-protocol lacp

 

port-channel 128 mode active

 

exit

 

protocol lldp

 

no advertise dcbx-tlv ets-reco

 

dcbx port-role auto-upstream

 

no shut

 

exit

 

Port-channel connecting S5000 switch needs

 

to have following configuration.

 

interface port-channel 128

 

portmode hybrid

 

switchport

 

fip-snooping port-mode fcf

 

• Server facing ports needs to below

 

configuration

 

portmode hybrid

 

switchport

 

protocol lldp

 

dcbx port-role auto-downstream

 

no shut

 

exit

S5000

Below configuration is prerequisite for S5000.

 

• Enable Fibre Channel capability and Full Fabric

 

mode.

 

feature fc

 

• Enable FC ports connecting to Compellent

 

storage array and FC ports connecting to other

 

S5000 switch via ISL links.

 

interface range fi 0/0 - 7

 

no shut

 

• Create DCB Map

 

dcb-map SAN_DCB_MAP

 

priority-group 0 bandwidth 60 pfc

 

off

 

priority-group 1 bandwidth 40 pfc on

 

priority-pgid 0 0 0 1 0 0 0 0

 

exit

14

Image 14
Contents Active System Manager Version 8.0 Quick Installation Guide Page Contents Configuring Dhcp or PXE on External Servers About this Document What is New in this ReleaseAccessing Online Help Important Note Other Documents You May NeedLicensing ASM Port and Protocol Information Deployment Prerequisites Installing Active System MangerInformation Prerequisites Page Page Prerequisites for M1000e with MXL, S5000, and Compellent MXLInterface range fi 0/0 7 no shut Prerequisites for Rack Server, S5000, and Compellent Dcbx port-role auto-downstream Prerequisites for Rack Server, S5000, Brocade and Compellent Interface vlan Vlan ID Create Vlan for FCoE Exit Feature fcoe feature npiv feature lacp Prerequisites for Rack Server, Cisco Nexus, and Compellent Interface vfc101 Conf feature npv Resource Create VSAN-instantiate it in the Vsan database FC feature needs to be enabled on the MXL System Center Virtual Machine Manager Scvmm Prerequisites Deploying ASM from VMware vSphere ClientDeploying ASM using Scvmm Deploying ASM on Hyper-V host Changing Dell Administrator Password Configuring Static IP Address in the Virtual ApplianceConfiguring ASM Virtual Appliance as PXE Boot Responder Customizing Virtual Machine Templates for VMware and Hyper-V Main Server=dellasm Master Agent Customizing Linux Template Rm /lib/udev/rules.d/75-persistent-net-generator.rulesCustomizing Windows Template Crontab -lPage Adding NetApp Ruby SDK Enable Http or HTTPs for NFS share Configuring NetApp Storage ComponentPage Completing Initial Configuration Page Deploying WinPE on the Virtual Appliance Adding OS Image Repositories Page Page Configure Dhcp on Windows 2012 Dhcp Server Create the Dhcp User ClassCreate the Dhcp Policy Create the Boot File Scope OptionConfigure Dhcp on Windows 2008 Dhcp Server Create the Dhcp User Class Configuring Dhcp for Linux Sample Dhcp Configuration