Graco SDM5 Recalibrating the Meter FIG, Choosing a Calibration Factor From the Calibration Table

Page 17

Recalibrating the Meter (FIG. 14)

The meter is shipped from the factory with the default calibration factor for 10W30 motor oil - at 70°F (21°C). This calibration factor is sufficiently accurate for most oils. If other fluids are used or if greater accuracy is required, the meter can be recalibrated by performing one of the following recalibration methods.

1.Choosing a Calibration Factor From the Calibration Table 1

Calibration factors provided in Table 1 (page 16), are only approximate, but sufficient for most appi- cations. For the most accuracy, use method 2,

Manual Calibration Procedure.

1.Use LEFT or RIGHT ARROW to move the curser to the Calibration Factor Field (K) .

2.Use the UP or DOWN ARROWS to manually adjust the Preset Calibration Factor up or down until the number displayed matches the calibration factor you have chosen from Table 1.

3.Press center, ENTER button to confirm new setting. New setting displays in Calibration Factor field (J).

4.Use the RIGHT ARROW button to move curser over Wrench icon.

5.Press center, ENTER button, to return to Main Setup Screen.

OR

2. Manual Calibration Procedure

See FIG. 14, page 16 for the Calibrate Screens 1 and 2 referenced in the following instructions.

When an English unit (gallon, quarts, pints) is set as the measurement unit on the Units/Limit Screen, page 15, use a one quart graduated cylinder to calibrate the meter.

When a System International Unit (SI) (Liter) is set as the measurement unit on the Units/Limit Screen, use a one Liter graduated cylinder to calibrate the meter.

1.Use the LEFT or RIGHT ARROWS to select START

(L) on Calibrate Screen 1.

2.Press the center, ENTER button to confirm selec- tion. Calibrate Screen 2 will appear.

Setup Mode Screens

3.Dispense exactly 1 quart (or 1 liter) of fluid into a calibrated 1 quart (or 1 liter) container.

The Calibration Factor will appear on the screen in the Calibration Factor field (J).

4.Use the LEFT or RIGHT ARROWS to select END

(L) on Calibrate Screen 2.

5.Press the center, ENTER button to confirm selec- tion. Calibrate Screen 1 will appear.

6.When you have finished making changes, use the RIGHT ARROW button to move curser over Wrench icon.

7.Press center, ENTER button, to return to Main Setup Screen.

To attain the most accurate calibration:

Use the manual calibration procedure (Method 2).

Use a certified, graduated cylinder; either 1-Quart or 1-Liter volume in the system of Units to be used (either English or SI) for real-time dispenses.

Calibrate using the exact fluid to be dispensed, at the temperature expected during dispense.

After calibration check your results by measuring a dispense.

Be sure to remove all fluid from graduated cylinder between calibration attempts.

Be sure meter is set to proper system of units for container you are using.

Once the meter has been calibrated, the unit of measure can be changed to any other unit, without the need for recalibration.

312865R

17

Image 17
Contents List of Models Important Safety InstructionsSDM5 Manual Dispense Electronic Meters ModelsModel Number Extension DescriptionExtension Description Nozzle Fluid Type SDM15 Manual Dispense Electronic MetersSDP5 Preset Dispense Electronic Meters SDP15 Preset Dispense Electronic Meters Skin Injection Hazard Fire and Explosion Hazard Typical Installations FIG InstallationMounting Bracket FIG Drum Mount Bracket FIGPre-Installation Procedure Pressure Relief ProcedureInstallation Procedure GroundingInstalling Tube Extension FIG Installing Meter FIGInstalling Nozzle FIG Navigation and Modes Meter OverviewWay Menu Navigation Button FIG Meter DisplayPreset Meters Setup Mode ScreensTo display the Home Screen Manual MetersDisplaying Setup Screen from an Operation Mode Screen Main Setup Screen FIGMain Screen Features FIG All MetersAll meters include C E Preset meters also include F G Manual Meters Preset MetersUnits/Limit Screen FIG For All MetersFluids Calibrate Screen FIGCalibration Number Recalibrating the Meter FIG Manual Calibration ProcedureChoosing a Calibration Factor From the Calibration Table To attain the most accurate calibrationFor Preset Meters Only Preset Screen FIGPreset Meters include D, P and Q To set Preset amounts FIGLanguage Screen Features D, S, and T Banner Screen Features D and RBanner Screen FIG Language Screen FIGHome Screen FIG Dispensing Fluid and Operation Mode ScreensAll Meters Manual Meters All Meters include Include a DTo dispense in Manual Mode To reset counter to zero after a dispensePreset shown Manual Dispense FIGSee for terms D L Preset Dispense FIGTo modify the amount selected QTS50 QTS To dispense in Preset ModeTo display Totals Screen Totals Screen FIGSee for terms F, G, M P Do not trigger meter when nozzle TroubleshootingProblem Cause Solution Troubleshooting Error Code Cause Solution Error CodesManual Mode only ErrReplacing the Battery ServiceSDP5 & SDP15 Meters Only DisassemblyTrip Rod Repair Remove and discard o-ring 5 FIG Cleaning Trip Rod Reassembly Ti11938ab Replace 4 screws A. Torque each to 15-25 inch pounds Qty Part Description SDM5 & SDM15 Manual Meters PartsRef Part Description 18a Part Description Qty SDP5 & SDP 15 Preset Meters Parts34c 34b 24d 24c 31a 24b 24a 24e 24f Nozzle 33 and Extension 20 Kits Nozzle 33 and Extension 20 Kits Part No. Description PSI bar Rating Nozzle 33 KitsThermal Relief Kits Technical Data Graco Information Graco Extended Metered Dispense Valve Warranty

SDP5, SDM5, SDM15, SDP15 specifications

The Graco SDP15, SDM15, SDM5, and SDP5 are innovative airless paint sprayers popular among both professionals and DIY enthusiasts. They represent a range of features and technologies that optimize painting efficiency, precision, and reliability.

The Graco SDP15 is designed for extensive projects and professional use. It boasts an impressive maximum operating pressure of 3000 PSI, allowing for smooth and even application of a variety of coatings, including heavier materials like paints and stains. One of its standout features is the ProControl system, which enables users to adjust the pressure settings on-the-fly, ensuring optimal performance for different surfaces and materials.

The SDM15 is another powerful option, particularly suited for medium to large jobs. This model features a robust motor and a compact design, making it both durable and portable. It includes an easy-to-use Control Pro technology, which minimizes overspray while delivering an even finish. Additionally, the SDM15 integrates a built-in filter, enhancing the longevity of the pump by preventing debris from clogging the system.

For lighter tasks or smaller projects, the Graco SDM5 and SDP5 models are excellent choices. The SDM5 is valued for its lightweight design and ease of maneuverability. It has a suitable PSI range for home improvement tasks, allowing for an efficient painting experience without the complexity. The convenient compact storage feature makes it ideal for homeowners and occasional users.

On the other hand, the SDP5 is specifically designed for users who prioritize user-friendliness. It includes features like a flexible suction tube, allowing users to paint directly from the can, reducing cleanup. The SDP5 also incorporates Graco’s exclusive SmartControl technology, ensuring consistent power and pressure throughout the spraying process.

All four models share key technologies such as the stainless-steel piston pump, which enhances durability and lifespan and the ability to handle a wide array of coatings without the need for thinning.

In conclusion, whether for professional use with the SDP15 and SDM15 or for home projects with the SDM5 and SDP5, Graco's lineup provides a range of versatile, efficient, and user-friendly options. Their focus on technology and practical features makes them a top choice for all painting needs.