Schneider Electric iFBZ, FBZ2, 3BZ2 Wiring Examples, Phase line Diagram, Single phase line Diagram

Page 16

EOCR-i3BZ/iFBZ/3BZ2/FBZ2

EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT,

EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT

Wiring Examples

3 phase line Diagram

EOCR-i3BZ/iFBZ

OL : b, GR : a

Caution

1. Do not use any External CT

2. Earth fault detection by built-in ZCT

3 phase line Diagram

EOCR-i3BZ/iFBZ

OL : 1a 1b, GR : 1a

Caution

1. Do not use any External CT

2. Earth fault detection by built-in ZCT

3 phase line Diagram

EOCR-i3BZ/iFBZ

OL : 1a 1b, GR : 1a

Caution

1. Do not use any External CT

2. Earth fault detection by built-in ZCT

Single phase line Diagram

EOCR-i3BZ/iFBZ

OL : b, GR : a

Caution

1. Do not use any External CT

2. Earth fault detection by built-in ZCT

Single line Diagram

 

 

 

 

 

FROM : BUSDUCT

EOCR-iFBZ

 

 

 

 

 

 

 

 

 

MCCF-A1-RF

 

 

 

 

 

MCCF-B1-RF

 

 

 

 

 

 

 

DM

DM

DM

DM

DM

P.T×3

EOCR

EOCR

EOCR

EOCR

EOCR

380/110V F

-iFBZ

-iFBZ

-iFBZ

-iFBZ

-iFBZ

 

 

DM

MAIN

MODBUS 485

MODBUS 485

MODBUS 485

MODBUS 485

MODBUS 485

MCCB

 

 

 

 

 

 

 

 

 

 

 

 

C.T

Y-

Y-

Y-

 

 

Single line Diagram

 

 

 

 

 

FROM : BUSDUCT

EOCR-FBZ2

 

 

 

MCCF-A1-RF

 

 

 

 

 

MCCF-B1-RF

 

 

 

 

 

 

 

DM

DM

DM

DM

DM

P.T×3

EOCR

EOCR

EOCR

EOCR

EOCR

380/110V F

 

 

-FBZ2

-FBZ2

-FBZ2

-FBZ2

-FBZ2

DM

MAIN

 

 

 

 

 

MCCB

 

 

 

 

 

 

 

 

 

 

 

 

C.T

Y-

Y-

 

Y-

 

16

Image 16
Contents Page Page Bottom hole & terminal type Applications Public institutions General Features EOCR-i3BZ/iFBZ/3BZ2/FBZ2Operating Condition & Setting Range Operation Time Protection functionsAuxillary functions Communication function Applicable to i3BZ/iFBZSpecifications Time-current characteristic curve Over current and time setting tips Over current Setting tips in definite TCC modeAlert Operation Pattern #3 Fail-safe operationCurrent display Front faceBar graph Buttons and Setting Sequence Phase digital ammeter functionButton Description Setting sequence and menu Parameter DescriptionAlert *1 Menu Parameter Description DefaultCommunication *2 Trip cause indication and fault records Control terminalsWiring Examples Phase line DiagramSingle phase line Diagram Single line DiagramDimensions Order Code Modbus network setting RS485 bus connectionStandard connection Bus connection through a SCA type junction box Head Office Iksan Plant