Furuno FE-700 installation manual Transducer, Type

Page 10

F type

Flush Mount Kit (F):

OP02-79-1 (001-229-290)

 

 

 

 

OP02-79-2 (001-229-300)

 

 

 

 

OP02-79-3 (001-229-310)

 

 

No.

Name

 

Type

Code no.

Qty

Remarks

1

Cosmetic

 

02-129-1041-0

100-279-270

1

OP02-79-1:N3.0

 

100-279-280

OP02-79-2:2.5GY5/1.5

panel

 

 

 

 

100-279-290

 

OP02-79-3:7.5GY7/2

 

 

 

 

 

2

Hex bolt

 

M6x12

000-162-897-1

4

 

 

0

 

 

 

 

 

 

 

3

Spring

 

M6

000-158-855-1

4

 

washer

 

0

 

 

 

 

 

 

1.Prepare a cutout in the mounting location whose dimensions are 210 (W) x 194 (H) mm.

2.Attach the cosmetic panel (02-129-1041-0) to the display unit with four hex bolts (M6x12) and four spring washers (M6).

3.Fix the display unit to the mounting location with four tapping screws (5x20).

S type

Flush Mount Kit (S):

OP02-80 (001-229-320)

 

 

No.

Name

Type

Code no.

Qty

Remarks

1

Fixing plate

02-129-1045-0

100-279-300

2

 

2

Wing bolt

M4x30

000-804-799

6

 

3

Hex bolt

M6x12

000-162-897-1

4

 

0

 

 

 

 

 

 

4

Spring

M6

000-158-855-1

4

 

washer

0

 

 

 

 

 

5

Wing nut

M4

000-863-306

6

 

1.Prepare a cutout in the mounting location whose dimensions are 194 x 194 mm.

2.Insert the display unit to the cutout.

3.Attach two fixing plates (02-129-1045-0) to the display unit with four hex bolts (M6x12) and spring four washers (M6).

4.Screw six wing bolts (M4x30) to wing nuts (M4).

5. Fasten the display unit with six wing bolts and nuts.

1.3 Transducer

The installation of the transducer and the tank should be accomplished by a dockyard referring to the installation drawings at the back of this manual. An example of transducer installation method is also shown in paragraph 1.3.2.

Note: Discussions should take place and agreement reached with the dockyard for sufficient reinforcement and watertightness of the hull to comply with the regulations concerned.

4

Image 10
Contents Navigational Echo Sounder FE-700 00080891011 Safety Instructions Standard Supply Optional SupplyIii System Configuration Display Unit Category of EquipmentMounting consideration Removing the cover Desktop mountingFlush mounting Transducer TypeExample of Transducer Installation TTF-5600 Mounting LocationDistribution Box Digital Depth Indicator FE-720 option Matching BoxType Transducer Switch Box EX-8 option Gate Valve GV-50B-6B, GV-200B-8B optionNut Washer Flange Wiring WiringMB-1200 DPYCYS-2.5, DPYCYS-1.5, TPYCYS-1.5 Shield Sheath Armor Core =1.5 mm =1.56mm Vinyl sheath Cable Fabrication of TTYCYS-4 Power Supply Cable from Ships Mains Transducer GroundAlarm system connection Digital Depth Indicator FE-720FE-720 setting Changing Power Specifications 100 VAC, 110-115 VAC, 200 VAC Ships MainsVDC Ships Mains Adjustments Transducer Setting49.6 m Setting the Time Open the system menu 2 referring to the operator’s manual70+6   #/ 76.+0 +26+10%1& 70+6 #& #& 52#42#465.+5614 Page Page Page Page Page Page Page Page Page Page Page Page Page Hatai Hatai Hatai Takahashi.T Hatai Hatai MAtsuguchi Matsuguchi Yamasaki Digital Depth Indicator Printer